4.Grease (supplied) both sides of the gasket 1 and the inner side of the spacer. Place the gasket 1 onto the spacer.

5.Clean the flange side of the gate valve, and place it on the gasket 1. The scale side of the gate valve should be up.

6.Fix stud bolts with washers and bolts loosely.

7.Keep seachest cap and shaft assembly free of dirt and dust.

8.Grease O-ring (P170) and seachest cap lightly, and attach O-ring (P170) and gasket 2 to the bottom of seachest cap.

O-ring (P170) and gasket 2 are attached by adhesion of grease.

9.Place the assembly made at step 8 on the gate valve.

10.Fix the assembly with bolts, nuts and washers loosely.

11.Unscrew nuts from flange 2, and confirm that shaft can be moved up and down smoothly by hand.

You will feel some resistance because of the O-ring (P135). (See the illustration on the previous page.)

Nut

Washer

Flange 2

12. Fasten the gate valve with bolts, nuts and washers above and below.

NOTE) When installing a transducer, do it before step 7 or after removing the seachest cap and the shaft assembly.

10

Image 16
Contents Navigational Echo Sounder FE-700 00080891011 Safety Instructions Standard Supply Optional SupplyIii System Configuration Display Unit Category of EquipmentMounting consideration Removing the cover Desktop mountingFlush mounting Transducer TypeExample of Transducer Installation TTF-5600 Mounting LocationDistribution Box Digital Depth Indicator FE-720 option Matching BoxType Transducer Switch Box EX-8 option Gate Valve GV-50B-6B, GV-200B-8B optionNut Washer Flange Wiring WiringMB-1200 DPYCYS-2.5, DPYCYS-1.5, TPYCYS-1.5 Shield Sheath Armor Core =1.5 mm =1.56mm Vinyl sheath Cable Fabrication of TTYCYS-4 Power Supply Cable from Ships Mains Transducer GroundAlarm system connection Digital Depth Indicator FE-720FE-720 setting Changing Power Specifications 100 VAC, 110-115 VAC, 200 VAC Ships MainsVDC Ships Mains Adjustments Transducer Setting49.6 m Setting the Time Open the system menu 2 referring to the operator’s manual70+6   #/ 76.+0 +26+10%1& 70+6 #& #& 52#42#465.+5614 Page Page Page Page Page Page Page Page Page Page Page Page Page Hatai Hatai Hatai Takahashi.T Hatai Hatai MAtsuguchi Matsuguchi Yamasaki Digital Depth Indicator Printer