4. ADJUSTMENTS

This section provides the procedures for initial set up of the equipment. The type of transducer used should be properly set before operating the equipment.

4.1Transducer Setting

Select the type of transducer used as follows.

1.Press the POWER Switch while pressing any key. Release the key when the following display appears.

EXTENSION MODE

+ : TRANSDUCER SETTING

- : TEST

▲: CLEAR MEMORY

▼: DEMONSTRATION

2. Press the [+] key to select TRANSDUCER SETTING.

TRANSDUCER SETTING

CHANGEOVER : AUTO MANUAL [FORE] XDR : N/A 50kHz 200kHz KEEL DIST. : 0.0 m(0.0-10.0)

[AFT] XDR : N/A 50 kHz 200kHz

KEEL DIST. : 0.0 m(0.0-10.0)

DEPTH(BELOW) TRANSDUCER KEEL DISP MODE : DUAL SINGLE

DISP ORDER*: AFT/FORE FORE/AFT OUTPUT* : FORE AFT

MEMORIZE* : DUAL FORE AFT

:To select item

-+: To set option

*Does not appear when DISP MODE is set to SINGLE.

3.Set the transducer(s) as shown below. Use [▲] or [▼] to select an item and [+] or [-] to set option.

a)CHANGEOVER sets how transducer(s) is connected to the FE-700. Select MANUAL for single transducer or transducers connected via Switch Box EX-8. Select AUTO for connection via Distribution Box MB-1200.

b)One transducer installed: Set FORE XDR to 50 kHz or 200 kHz, depending on actual installation. Leave AFT XDR set to “N/A."

Two transducers installed: Set FORE XDR and AFT XDR to 50 kHz or 200 kHz, depending on actual installation.

c)KEEL DIST sets the distance from transducer to keel of the ship.

d)DEPTH (BELOW) selects the method of depth indication. TRANSDUCER for depth indication below the transducer (except DBS mode), or KEEL for depth indication below the keel.

e)DISP MODE sets the function of the MODE switch in case of dual frequencies. Select DUAL to show the dual frequency display (fore and aft), or SINGLE to show single frequency display.

22

Image 28
Contents Navigational Echo Sounder FE-700 00080891011 Safety Instructions Standard Supply Optional SupplyIii System Configuration Display Unit Category of EquipmentMounting consideration Removing the cover Desktop mountingFlush mounting Transducer TypeExample of Transducer Installation TTF-5600 Mounting LocationDistribution Box Digital Depth Indicator FE-720 option Matching BoxType Transducer Switch Box EX-8 option Gate Valve GV-50B-6B, GV-200B-8B optionNut Washer Flange Wiring WiringMB-1200 DPYCYS-2.5, DPYCYS-1.5, TPYCYS-1.5 Shield Sheath Armor Core =1.5 mm =1.56mm Vinyl sheath Cable Fabrication of TTYCYS-4 Power Supply Cable from Ships Mains Transducer GroundAlarm system connection Digital Depth Indicator FE-720FE-720 setting Changing Power Specifications 100 VAC, 110-115 VAC, 200 VAC Ships MainsVDC Ships Mains Adjustments Transducer Setting49.6 m Setting the Time Open the system menu 2 referring to the operator’s manual70+6   #/ 76.+0 +26+10%1& 70+6 #& #& 52#42#465.+5614 Page Page Page Page Page Page Page Page Page Page Page Page Page Hatai Hatai Hatai Takahashi.T Hatai Hatai MAtsuguchi Matsuguchi Yamasaki Digital Depth Indicator Printer