Furuno FE-700 installation manual Safety Instructions

Page 3

SAFETY INSTRUCTIONS

WARNING

ELECTRICAL SHOCK HAZARD

Do not open the equipment unless totally familiar with electrical circuits and service manual.

Only qualified personnel should work inside the equipment.

Turn off the power at the switchboard before beginning the installation.

Fire or electrical shock can result if the power is left on.

Do not install the equipment where it may get wet from rain or water splash.

Water in the equipment can result in fire, electrical shock or equipment damage.

Be sure no water leaks in at the trans- ducer mounting location.

Water leakage can sink the vessel. Also confirm that the transducer will not loosen by ship’s vibration. The installer of the equipment is solely responsible for the proper installation of the equipment. FURUNO will assume no responsibility for any damage associated with improper installation.

Be sure that the power supply is compatible with the voltage rating of the equipment.

Connection of an incorrect power supply can cause fire or equipment damage. The voltage rating of the equipment appears on the label above the power connector.

CAUTION

Observe the following compass safe distances to prevent deviation of a magnetic compass:

 

Standard

Steering

 

compass

compass

 

 

 

Display

0.50 m

0.40 m

unit

 

 

 

 

 

Distribution￿

1.90 m

1.15 m

Box

 

 

 

 

 

Matching Box

0.50 m

0.40 m

 

 

 

Transducer

1.00 m

0.60 m

Switch Box

(option)

 

 

Junction Box

0.30 m

0.30 m

(option)

 

 

 

 

 

Digital depth

0.50 m

0.40 m

indicator (option)

 

 

 

 

 

Distribution box

0.30 m

0.30 m

(option)

 

 

 

 

 

When handling the transducer cable, keep in mind following points.

Keep the cable away from oil and fuel.

Keep the cable away from the place where it may be damaged during the installation.

Do not paint the cable.

The sheath of the transducer cable is made of chlorophrene rubber (or vinyl chloride). Therefore, do not paint the sheath with organic liquid (such as toluene) since it may harm the sheath.

i

Image 3
Contents Navigational Echo Sounder FE-700 00080891011 Safety Instructions Optional Supply Standard SupplyIii System Configuration Category of Equipment Display UnitMounting consideration Desktop mounting Removing the coverFlush mounting Type TransducerMounting Location Example of Transducer Installation TTF-5600Distribution Box Matching Box Digital Depth Indicator FE-720 optionType Gate Valve GV-50B-6B, GV-200B-8B option Transducer Switch Box EX-8 optionNut Washer Flange Wiring WiringMB-1200 DPYCYS-2.5, DPYCYS-1.5, TPYCYS-1.5 Shield Sheath Armor Core =1.5 mm =1.56mm Vinyl sheath Cable Fabrication of TTYCYS-4 Power Supply Cable from Ships Mains Ground TransducerDigital Depth Indicator FE-720 Alarm system connectionFE-720 setting 100 VAC, 110-115 VAC, 200 VAC Ships Mains Changing Power SpecificationsVDC Ships Mains Transducer Setting Adjustments49.6 m Open the system menu 2 referring to the operator’s manual Setting the Time70+6   #/ 76.+0 +26+10%1& 70+6 #& #& 52#42#465.+5614 Page Page Page Page Page Page Page Page Page Page Page Page Page Hatai Hatai Hatai Takahashi.T Hatai Hatai MAtsuguchi Matsuguchi Yamasaki Digital Depth Indicator Printer