1.7 Transducer Switch Box EX-8 (option)

If two transducers are installed, the transducers switch box is required. Locate the transducer switch box near the display unit considering length of the interconnection cable. Select the bright place where the panel of equipment can be watched. Use only the screws supplied on the terminal inside to make connections. Use of other screws may cause a short circuit. Compass safe distances are as follows; standard compass: 1.00 m, Steering compass: 0.60 m.

1.8 Gate Valve GV-50B-6B, GV-200B-8B (option)

Assemble the Gate Valve as shown below. Refer to the drawing at the end of this manual.

1.Disassemble the gate valve assembled tentatively: spacer, gasket1, gate valve, gasket 2, O-ring (P170), seachest cap and shaft assembly.

When assembling the gate valve, use original washers, bolts and nuts. Keep the bottom of the seachest cap and the shaft free of dust and be careful not to damage them.

SCALE

GATE VALVE

WASHER

NUT

BOLT

SHAFT

SEACHEST CAP

NUT

1

WASHER O-RING (P135)

O-RING (P170)

GASKET1

GASKET2

SPACER

2.Weld the spacer to the hull bottom.

The hull side of the spacer should be flush with the hull bottom. Be careful not to damage the side fixed to the gate valve.

3.Clean the side of the spacer to be fixed to the gate valve.

9

Image 15
Contents Navigational Echo Sounder FE-700 00080891011 Safety Instructions Optional Supply Standard SupplyIii System Configuration Category of Equipment Display UnitMounting consideration Desktop mounting Removing the coverFlush mounting Type TransducerMounting Location Example of Transducer Installation TTF-5600 Distribution Box Matching Box Digital Depth Indicator FE-720 optionType Gate Valve GV-50B-6B, GV-200B-8B option Transducer Switch Box EX-8 optionNut Washer Flange Wiring WiringMB-1200 DPYCYS-2.5, DPYCYS-1.5, TPYCYS-1.5 Shield Sheath Armor Core =1.5 mm =1.56mm Vinyl sheath Cable Fabrication of TTYCYS-4 Power Supply Cable from Ships Mains Ground TransducerDigital Depth Indicator FE-720 Alarm system connectionFE-720 setting 100 VAC, 110-115 VAC, 200 VAC Ships Mains Changing Power SpecificationsVDC Ships Mains Transducer Setting Adjustments49.6 m Open the system menu 2 referring to the operator’s manual Setting the Time70+6   #/ 76.+0 +26+10%1& 70+6 #& #& 52#42#465.+5614 Page Page Page Page Page Page Page Page Page Page Page Page Page Hatai Hatai Hatai Takahashi.T Hatai Hatai MAtsuguchi Matsuguchi Yamasaki Digital Depth Indicator Printer