Furuno FE-700 Setting the Time, Open the system menu 2 referring to the operator’s manual

Page 30

4.2Setting the Time

1.Open the system menu 2 referring to the operator’s manual.

SYSTEM MENU 2

MENU SELECT

 

1

2

 

3

 

 

 

 

 

 

 

TIME ADJUST

 

INTERNAL

EXTERNAL

DAY

1

 

 

 

 

 

MONTH

 

JAN

 

 

 

 

 

 

YEAR

 

2009

( 2100)

HOUR

0

 

 

 

(0 23)

MINUTE

1

 

 

 

(0 59)

SECOND

42

 

 

 

(0 59)

01 JAN 2009

00:01:06

TS: To select item

- +: To set option

Select other mode to exit.

System menu 2

2.Press [▼] key to select TIME ADJUST. Select INTERNAL to use the internal clock. Set day, month, year, hour, minute and second with [+] or [-] key. Select EXTERNAL to use time data from equipment that outputs time in ZDA format. At TIME DIFFERENCE field, select AUTO or MANUAL. MANUAL requires entry of time difference.

SYSTEM MENU 2

MENU SELECT

1

2

 

 

3

TIME ADJUST

INTERNAL

 

 

 

EXTERNAL

TIME DIFFERENCE

AUTO

 

 

MANUAL

01 JAN 2009 00:02:10

TS : To select item

-+: To set option. Select other mode to exit.

SYSTEM MENU 2

MENU SELECT

1

 

2

 

3

 

TIME ADJUST

INTERNAL

 

EXTERNAL

TIME DIFFERENCE

AUTO

 

 

 

 

MANUAL

 

TIME DIFF HOUR

0

 

 

 

 

 

 

 

(0~13)

 

 

TIME DIFF MIN

0

 

(0~59)

 

 

TIME DIFF SIGN

-

 

(0~59)

 

 

01 JAN

2009

00:02:10

 

TS : To select item

-+: To set option. Select other mode to exit.

TIME ADJUST set to EXTERNAL

TIME DIFFERENCE set to MANUAL

24

Image 30
Contents Navigational Echo Sounder FE-700 00080891011 Safety Instructions Standard Supply Optional SupplyIii System Configuration Category of Equipment Display UnitMounting consideration Removing the cover Desktop mountingFlush mounting Transducer TypeExample of Transducer Installation TTF-5600 Mounting LocationDistribution Box Digital Depth Indicator FE-720 option Matching BoxType Transducer Switch Box EX-8 option Gate Valve GV-50B-6B, GV-200B-8B optionNut Washer Flange Wiring WiringMB-1200 DPYCYS-2.5, DPYCYS-1.5, TPYCYS-1.5 Shield Sheath Armor Core =1.5 mm =1.56mm Vinyl sheath Cable Fabrication of TTYCYS-4 Power Supply Cable from Ships Mains Transducer GroundAlarm system connection Digital Depth Indicator FE-720FE-720 setting Changing Power Specifications 100 VAC, 110-115 VAC, 200 VAC Ships MainsVDC Ships Mains Adjustments Transducer Setting49.6 m Setting the Time Open the system menu 2 referring to the operator’s manual70+6   #/ 76.+0 +26+10%1& 70+6 #& #& 52#42#465.+5614 Page Page Page Page Page Page Page Page Page Page Page Page Page Hatai Hatai Hatai Takahashi.T Hatai Hatai MAtsuguchi Matsuguchi Yamasaki Digital Depth Indicator Printer
Related manuals
Manual 44 pages 39.49 Kb