Graham Field 14423-4, 14423-2, 14423-8 user manual Pocket Doppler WATER-RESISTANT Probes, Battery

Page 17

POCKET DOPPLER WATER-RESISTANT PROBES

The 2.0 MHz, 4.0 MHz, and 8.0 MHz water-resistant probes connect to the main unit of the Grafco Pocket Doppler via the probe socket. The following table lists and describes the main information on each probe's label in order of ap- pearance:

Pocket Doppler Water-Resistant Probe Label Table

Picture of Probe

Probe Label

2.0 MHz

4.0 MHz

8.0 MHz

Text

Water-Resistant

Water-Resistant

Water-Resistant

 

Probe

Vascular

Vascular

 

 

Probe *

Probe *

CD

Continuous Wave Doppler

 

X.0 (Central

Central

Central

Central

Frequency)

frequency =

frequency =

frequency =

 

2.0 MHz

4.0 MHz

8.0 MHz

A

Probe version number

 

 

 

 

SNxxxxx:

Probe Serial Number

 

 

 

 

Water-Resistant

The probe is water-resistant

 

IPX8

Water Ingress Protection Code, which indicates

(Water-Resistant)

this probe can work continuously for 5 hours when

 

immersed in water up to one meter deep.

* Vascular probes are used to monitor arteries and veins

BATTERY

See Section 5, SETUP, for battery installation and replace- ment instructions.

WARNING: Use only 9V alkaline batteries (IEC Type No. 6LR61/6LF22 or equivalent) in this device.

14423-INS-LAB-RevD11

17

Image 17 Contents
Ultrasound Pocket Doppler Contents Intended USE of this Device Included FeaturesIntroduction Product Description Optional AccessoriesSafety Guidance Safety InformationSafety Precautions INS-LAB-RevD11 INS-LAB-RevD11 INS-LAB-RevD11 Symbols Unpacking HandlingGF Health PRODUCTS, INC. Freight Policy Inspection StorageAppearance and Features Ultrasound Pocket Doppler and AccessoriesSocket Jack Definition PowerButton Attachment Battery Rear Panel Feature Function Pocket ClipSocket Name Picture Top Panel FeatureMode Button Left Panel Feature Function Volume ControlPocket Doppler WATER-RESISTANT Probes BatteryInstalling or Replacing the Battery SetupINS-LAB-RevD11 Probe Operation OperationRemoving the Probe from the Pocket Doppler Placing the Probe in the Pocket DopplerSwapping Probes Turning on the Pocket DopplerFH Monitoring with 2.0 MHz Water-Resistant Probe Fetal Heart FH MonitoringVascular Monitoring with 4.0 or 8.0 MHZ Probe Optional Turning OFF the Pocket Doppler Replacing the BatteryMaintenance MaintenanceCleaning the Pocket Doppler CleaningCleaning the Pocket Doppler Probe Disinfecting the Pocket Doppler Probe DisinfectionSafety SpecificationsPhysical Power BatteryUltrasound Limited Warranty INS-LAB-RevD11 GF Health Products, Inc. Graham-Field EC Declaration of Conformity Appendix A, EC Declaration of ConformityGuidance and MANUFACTURER’S Declaration Appendix B, EMC InformationRF IEC DistanceFrequency of transmitter m Recommended Separation DistancesRated Separation distance according to INS-LAB-RevD11 Overall Sensitivity 2 MHz Probe Appendix C, Overall Sensitivity=Ad+B+C Index INS-LAB-RevD11
Related manuals
Manual 44 pages 62.72 Kb Manual 44 pages 38 Kb