Graham Field 14423-2, 14423-8, 14423-4 user manual INS-LAB-RevD11

Page 6

WARNINGS

WARNING: Federal Law (USA) restricts this device to sale by or on the order of a physician. This product should not be used unless the operator has been in- structed by a qualified healthcare professional.

WARNING: Do not use the Grafco Pocket Doppler in a flammable atmosphere where concentrations of flam- mable anesthetics or other materials may occur.

WARNING: Do not expose batteries to heat.

WARNING: Do not attempt to charge alkaline batter- ies; they may leak or catch on fire.

WARNING: DO NOT simultaneously touch signal in- put or output connector and the patient.

WARNING: Accessory equipment connected to the analog and digital interfaces must be certified accord- ing to the respective IEC standards (e.g. IEC 950 for data processing equipment and IEC 60601-1 for medi- cal equipment). Furthermore all configurations shall comply with the valid version of the system stan- dard IEC 60601-1-1. Anyone who connects additional equipment to the signal input connector or signal output connector configures a medical system, and is therefore responsible that the system complies with the requirements of the valid version of the system standard IEC 60601-1-1. If in doubt, consult your GF Health Products, Inc. authorized distributor.

WARNING: The Grafco Pocket Doppler is a tool to aid the healthcare professional and should not be used in place of normal fetal monitoring.

WARNING: Exposure to ultrasound should be kept as low as reasonably achievable. This is considered to be good practice and should be observed at all times.

WARNING: Replace the battery at least 6 feet (1.5 me- ters) from the patient.

14423-INS-LAB-RevD11

6

Image 6 Contents
Ultrasound Pocket Doppler Contents Included Features IntroductionIntended USE of this Device Optional Accessories Product DescriptionSafety Information Safety PrecautionsSafety Guidance INS-LAB-RevD11 INS-LAB-RevD11 INS-LAB-RevD11 Symbols Handling GF Health PRODUCTS, INC. Freight PolicyUnpacking Storage InspectionUltrasound Pocket Doppler and Accessories Appearance and FeaturesPower ButtonSocket Jack Definition Rear Panel Feature Function Pocket Clip Attachment BatteryTop Panel Feature Socket Name PictureLeft Panel Feature Function Volume Control Mode ButtonBattery Pocket Doppler WATER-RESISTANT ProbesSetup Installing or Replacing the BatteryINS-LAB-RevD11 Removing the Probe from the Pocket Doppler OperationProbe Operation Placing the Probe in the Pocket DopplerTurning on the Pocket Doppler Swapping ProbesFetal Heart FH Monitoring FH Monitoring with 2.0 MHz Water-Resistant ProbeVascular Monitoring with 4.0 or 8.0 MHZ Probe Optional Replacing the Battery Turning OFF the Pocket DopplerMaintenance MaintenanceCleaning Cleaning the Pocket DopplerCleaning the Pocket Doppler Probe Disinfection Disinfecting the Pocket Doppler ProbeSpecifications SafetyPower Battery PhysicalUltrasound Limited Warranty INS-LAB-RevD11 GF Health Products, Inc. Graham-Field Appendix A, EC Declaration of Conformity EC Declaration of ConformityAppendix B, EMC Information Guidance and MANUFACTURER’S DeclarationDistance RF IECRecommended Separation Distances Rated Separation distance according toFrequency of transmitter m INS-LAB-RevD11 Appendix C, Overall Sensitivity Overall Sensitivity 2 MHz Probe=Ad+B+C Index INS-LAB-RevD11