Graham Field 14423-4, 14423-2, 14423-8 user manual INS-LAB-RevD11

Page 8

NOTICES

sNOTICE: The main unit of the Grafco Pocket Doppler is designed for continuous normal operation. Do not immerse or submerge in any liquid.

sNOTICE: Keep the Pocket Doppler and its environ- ment clean and dust-free. Protect the device from vi- bration, corrosive medicine, and high temperatures.

sNOTICE: Do not use high-temperature sterilizing pro- cess, low temperature steam, E-beam, or gamma ra- diation sterilization on this device or its accessories.

sNOTICE: If the Pocket Doppler will not be used for a prolonged period of time, remove the battery from the device.

sNOTICE: Keep the battery away from objects or mate- rials with static electric charges.

sNOTICE: If the battery terminals become dirty, wipe them with a clean, dry cloth before using the battery.

sNOTICE: Batteries have life cycles. If the battery use time shortens noticeably, the battery's life cycle is over. Replace the old battery with a new one of the same size and type. Use only batteries recommended by GF Health Products, Inc.

sNOTICE: Remove a battery whose life cycle is over from the monitor immediately.

sNOTICE: For information on installing and removing the battery from the monitor, see Section 5, SETUP.

sNOTICE: Dispose of the battery in accordance with lo- cal regulations.

sNOTICE: Do not dispose of this device with house- hold waste. Dispose of this device in accordance with your local laws and regulations.

14423-INS-LAB-RevD11

8

Image 8
Contents Ultrasound Pocket Doppler Contents Intended USE of this Device Included FeaturesIntroduction Optional Accessories Product DescriptionSafety Guidance Safety InformationSafety Precautions INS-LAB-RevD11 INS-LAB-RevD11 INS-LAB-RevD11 Symbols Unpacking HandlingGF Health PRODUCTS, INC. Freight Policy Storage InspectionUltrasound Pocket Doppler and Accessories Appearance and FeaturesSocket Jack Definition PowerButton Rear Panel Feature Function Pocket Clip Attachment BatteryTop Panel Feature Socket Name PictureLeft Panel Feature Function Volume Control Mode ButtonBattery Pocket Doppler WATER-RESISTANT ProbesSetup Installing or Replacing the BatteryINS-LAB-RevD11 Operation Probe OperationRemoving the Probe from the Pocket Doppler Placing the Probe in the Pocket DopplerTurning on the Pocket Doppler Swapping ProbesFetal Heart FH Monitoring FH Monitoring with 2.0 MHz Water-Resistant ProbeVascular Monitoring with 4.0 or 8.0 MHZ Probe Optional Replacing the Battery Turning OFF the Pocket DopplerMaintenance MaintenanceCleaning Cleaning the Pocket DopplerCleaning the Pocket Doppler Probe Disinfection Disinfecting the Pocket Doppler ProbeSpecifications SafetyPower Battery PhysicalUltrasound Limited Warranty INS-LAB-RevD11 GF Health Products, Inc. Graham-Field Appendix A, EC Declaration of Conformity EC Declaration of ConformityAppendix B, EMC Information Guidance and MANUFACTURER’S DeclarationDistance RF IECFrequency of transmitter m Recommended Separation DistancesRated Separation distance according to INS-LAB-RevD11 Appendix C, Overall Sensitivity Overall Sensitivity 2 MHz Probe=Ad+B+C Index INS-LAB-RevD11