Graham Field 14423-4, 14423-2, 14423-8 user manual Appendix A, EC Declaration of Conformity

Page 35

10 APPENDIX A, EC DECLARATION OF CONFORMITY

EC Declaration of Conformity

Manufactured for

GF Health Products, Inc., 2935 Northeast Parkway,

 

Atlanta, GA 30360

 

 

Product

Ultrasound Pocket Doppler

 

 

Classification

(MDD, Annex IX): IIa

We herewith declare that the above mentioned product(s) meet the transposition into national law, the provisions of Council Directive 93/42/EEC of 14 June 1993 concerning medical devices - as amended by Directive 98/79/EC on in vitro diagnostic medical devices.

All supporting documentation is retained at the premises of the manufacturer.

Directives

General Applicable Directives: Medical Device

 

Directive: COUNCIL DIRECTIVE 93/42/EEC of 14

 

June 1993 concerning medical devices (MDD 93/42/

 

EEC).

Standards applied

EN ISO 9001, ISO13485, EN ISO14971, EN ISO10993-

 

1, IEC 601-1, EN 60601-1-1, BS EN 60601-1-4, IEC

 

60601-1-2, EN 61157, EN 1041, EN 60417-2-2000,

 

IEC/TR 60878-2003, EN 980, EN 55011, ISO 1000, YY

 

0111-93, EN 61266, EN ISO 780 , GB/T 14740, GB/T

 

15464

Notified Body

TÜV SÜD Product Service GmbH, Ridlerstr 65, D-

 

80339 MÜnchen, Germany.

Identification

 

number

 

 

 

14423-INS-LAB-RevD11

35

Image 35
Contents Ultrasound Pocket Doppler Contents Intended USE of this Device Included FeaturesIntroduction Product Description Optional AccessoriesSafety Guidance Safety InformationSafety Precautions INS-LAB-RevD11 INS-LAB-RevD11 INS-LAB-RevD11 Symbols Unpacking HandlingGF Health PRODUCTS, INC. Freight Policy Inspection StorageAppearance and Features Ultrasound Pocket Doppler and AccessoriesSocket Jack Definition PowerButton Attachment Battery Rear Panel Feature Function Pocket ClipSocket Name Picture Top Panel FeatureMode Button Left Panel Feature Function Volume ControlPocket Doppler WATER-RESISTANT Probes BatteryInstalling or Replacing the Battery SetupINS-LAB-RevD11 Placing the Probe in the Pocket Doppler OperationProbe Operation Removing the Probe from the Pocket DopplerSwapping Probes Turning on the Pocket DopplerFH Monitoring with 2.0 MHz Water-Resistant Probe Fetal Heart FH MonitoringVascular Monitoring with 4.0 or 8.0 MHZ Probe Optional Turning OFF the Pocket Doppler Replacing the BatteryMaintenance MaintenanceCleaning the Pocket Doppler CleaningCleaning the Pocket Doppler Probe Disinfecting the Pocket Doppler Probe DisinfectionSafety SpecificationsPhysical Power BatteryUltrasound Limited Warranty INS-LAB-RevD11 GF Health Products, Inc. Graham-Field EC Declaration of Conformity Appendix A, EC Declaration of ConformityGuidance and MANUFACTURER’S Declaration Appendix B, EMC InformationRF IEC DistanceFrequency of transmitter m Recommended Separation DistancesRated Separation distance according to INS-LAB-RevD11 Overall Sensitivity 2 MHz Probe Appendix C, Overall Sensitivity=Ad+B+C Index INS-LAB-RevD11