Furuno GP-1850D installation manual Antenna unit, Ground, Extending antenna cable length

Page 11
CAUTION
Ground the equipment to prevent electrical shock and mutual interference.

Antenna unit

Connect the antenna cable to the ANT connector.

Ground

The display unit contains several CPUs.

While they are operating, they radiate noise, which can interfere with radio equipment. Ground the unit to prevent interference. The grounding wire should

be 1.25 sq or larger and as short as possible. Connect the grounding wire to ship's ground. On a fiberglass boat,

it is best to install a ground plate that measures about 20 cm by 30 cm on the outside of the hull bottom to provide a ground point. If this is not practical, the engine block can be used.

Also, the antenna unit GPA-018S type antenna units should be grounded.

Note: Use a “closed” lug to make the ground connection at the display unit. Do not

use an “open-type” lug ().

Extending antenna cable length

The standard cable is 10m long. For extension, in case of the GPA-016, GPA- 018S, GPA-019S an antenna cable set of 15m, 30m or 50m is available. Exten- sion cable cannot be used with the GPA-017 or GPA-018.

Extension cable line-up (in case of 30 m or 50 m)

Fabricate the end of the antenna cable and attach the co- axial connector. Details are shown on next page.

Antenna Unit

 

 

GPA-016

 

 

GPA-018S

Conversion

: Connector

GPA-019S

Cable Assy.

 

 

 

1 m

 

Antenna Cable

 

 

 

 

 

To display unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 m or 50 m

 

 

 

1 m

 

 

 

 

 

 

 

 

 

 

 

 

Fabricate locally. (See next page.)

Figure 2-3 Cable extension

Waterproofing connector

Wrap connector with vulcanizing tape and then vinyl tape.

Bind the tape end with cable-tie.

Figure 2-4 Waterproofing connector

2-2

Image 11
Contents Wiring Initial Settings Installation of Dgps Beacon ReceiverFirst Edition FEB Safety Instructions for the Installer Safety InstructionsOptional equipment Equipment ListsStandard supply Iii Display Unit System ConfigurationMounting considerations Installation of Standard EquipmentInstallation of Display Unit Tabletop, overhead mounting Mounting procedureFlush mounting of display unit Installation of Antenna UnitPower cable WiringExtending antenna cable length Antenna unitGround How to attach the N-P-8DFB connector Nmea port Initial SettingsNmea Setting RTCM104OUTPUT Dgps portInput/Output data sentences Output Data SentencesAntenna Height Baud Rate Setting GP-1850D onlyBeacon Baud Rate Beacon Frequency Setting GP-1850D onlyBeacon Frequency Auto HP-2N Installation of Dgps Beacon Receiver for GP-1850Procedure DisassemblyDismounting chassis assembly Installation of Dgps receiverInstallation of Dgps beacon receiver Wiring the Cable assembly Attaching chassis assembly 10 Memory, I/O Test Display Checking the Dgps installation11 Connecting Dgps beacon receiver Connecting Dgps beacon receiverPage Page Page Page Page Page Page Page Page Page Page Page