Graco 312497F 4a. Master Divider Valve Equipped With Performance Indicator

Page 14

Repair

4a. Master Divider Valve Equipped With Performance

Indicator

With manual pump connected to the master divider valve as outlined in Locating Blockages, Step 3, raise pressure to 2000 psi. The indicators in the indicator ports will signal the location of the block- age. An indicator in the up position indicates pres- sure is in that outgoing line and signals the blockage is in the area being served from this outlet (FIG. 11).

If no indicator pins are protruding, the blockage is in the master divider valve.

HAND PUMP

LUBE

OUTLETS

INDICATOR PIN UP

MASTER

DIVDER

VALVE

SECONDARY

DIVIDER

VALVE

TI11103

FIG. 11

4b. Master Divider Valve Equipped Without Performance

Indicator

1)With manual pump connected to the master divider valve as outlined in Locating Blockages, Step 3, raise pressure to 2000 psi.

2)Remove, one at a time, each indicator port plug and attempt to operate manual pump after each plug is removed. Do not exceed 2000 psi.

3)If pressure drops and the master cycles freely after an indicator port plug is removed, then blockage is downstream in the area that is being served from that outlet. See Locating Block- ages, Step 3.

NOTE:

If all indicator port plugs are removed, the master will not cycle. Blockage is in this divider valve.

When indicator port plug of a blocked area is removed, a small shot of trapped lubricant will usu- ally surge out of this outlet as the inlet pressure on the divider valve drops.

If testing (Step 4) indicates a blockage in the master divider valve, this divider valve must be disassem- bled and cleaned. See Clean Divider Valve, Step 7, page 15.

HAND PUMP

SYSTEM PUMP

LUBE

OUTLETS

INDICATOR PORT

PLUGS

MASTERREMOVED DIVDER

VALVE

SECONDARY

DIVIDER

VALVE

TI11104

FIG. 12

5.If in Step 4, a blockage has been indicated downstream of the master divider valve, install a manual pump in the indicator port of the master divider valve that is common to the blocked area. (See FIG. 12).

a.Proceed to downstream secondary divider valve and remove all indicator port plugs.

b.Slowly operate manual pump. If lubricant can be discharged freely through each of the indicator ports of this divider valve, the blockage is not in the supply line or the divider valve. Go to step 6.

If lubricant is not freely discharged through open indicator ports of the second divider valve, the blockage is in this divider valve or its supply line. Disconnect supply line at secondary inlet

14

312497F

Image 14
Contents Divider Type Maximum Pressure Lube PointsPressure kPSI SectionsPressure Relief Procedure Typical Divider Valve Combinations SetupComponent Identification Divider ValvesPrefilling Lubricant Distributor Lines Filling Secondary-to-Lube Point LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Repair Section Air purging afterTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Bleed Hose Here Lube Point Secondary Master Rupture Indicator Performance IndicatorsReset Indicator with Memory Automatic Relief Indicator4a. Master Divider Valve Equipped With Performance Indicator Torque Values *see , Assembly Torque ft-lbs MSP/MH MXP MGOContamination Blockage Separation BlockageMD Series Technical DataDimensions PartsMJ Series Lbs oz 1.55 kgParts MSP Series Crossport Plate Optional Parts MSP Series 312497F MHH Series Lube Outlet Inlet Typical Part No. Description MXP Series Ti11477 Parts MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 Parts MX Series Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator Rupture-to-Atmosphere Indicator with Spud AssemblySingling and Crossporting Bar Assemblies Cycle IndicatorsRupture Discs 1175Part Numbers Cycle SwitchesCycle Counters Part No Proximity Cycle Switches Description Type Part Number Pins SealProximity Switch Connection Cables Connection Cables forGraco Standard Warranty Graco Information