Graco 312497F Setup, Component Identification, Typical Divider Valve Combinations, Divider Valves

Page 3

Setup

The divider valve is shipped ready to install in your sys- tem. It has been factory-tested and should not require any additional modification.

NOTICE

Do not install a divider valve into a system rated for more than the valve’s maximum operating pressure. This type of installation could result in o-ring damage and cause the divider valve to leak.

To install the divider valve in your system:

1.Determine an appropriate, remote mounting loca- tion.

2.Install a rupture to atmosphere fitting with a blow-out disk that is rated for 7,500 psi or less between the force feed lubricator pump and master divider valve inlet.

3.Install an analog pressure gauge at the inlet to the divider valve.

4.Install a slow or no cycle shutdown in one of the pis- ton enclosure plugs. Program it to shut down after no more than 180 seconds without a complete cycle.

5.Torque. See Table 4 on page 15.

As long as lubricant is supplied under pressure to the inlet section of the divider assembly, valves sections will continue to operate in a progressive manner. Divider assemblies always follow a constant discharge pattern. Whenever lubricant flow ceases, the valving pistons will stop. When flow resumes, it will start again at the same point in the discharge cycle.

Setup

Component Identification

 

Inlet

Valve

Section

 

Section

 

 

Indicator/ Port Plug

 

Crossport

 

Plate

 

End Plug

 

Subplates with

 

Output Ports

End

Section

TI11117

Tie Rod Nut

FIG. 1

Table 3: Typical Divider Valve

Combinations

 

 

TYPE OF

MASTER

SECONDARY

APPLICATION

 

 

 

MJ

MD

Machine tools, Printing,

 

 

Wire Forging &

 

 

Packaging Machinery

 

 

 

MSP

MJ, MSP

Machine tools, Textile,

 

 

Glass & Can Machinery,

 

 

Mobile Equipment

 

 

 

MX, MXP

MX, MXP, MSP

Cranes, Presses, Steel

 

 

Mills, etc.

 

 

 

MGO

MX

Levellers, Shears,

 

 

Conveyors, etc.

 

 

 

Divider Valves

ASeries-Flo type divider valve is a manifold proportion- ing device consisting of an inlet and end section plus a minimum of three valve sections. The divider valve is manifolded together with tie rods and nuts. A master divider valve is the first divider valve downstream from the lube pump. A secondary divider valve is any divider valve receiving lubricant from the master divider valve.

312497F

3

Image 3
Contents Sections Maximum Pressure Lube PointsPressure kPSI Divider TypePressure Relief Procedure Divider Valves SetupComponent Identification Typical Divider Valve CombinationsFilling Secondary-to-Lube Point Lines Prefilling Lubricant Distributor LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Section Air purging after RepairTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Bleed Hose Here Lube Point Secondary Master Automatic Relief Indicator Performance IndicatorsReset Indicator with Memory Rupture Indicator4a. Master Divider Valve Equipped With Performance Indicator MSP/MH MXP MGO Torque Values *see , Assembly Torque ft-lbsSeparation Blockage Contamination BlockageParts Technical DataDimensions MD SeriesLbs oz 1.55 kg MJ SeriesParts MSP Series Crossport Plate Optional Parts MSP Series 312497F MHH Series Lube Outlet Inlet Typical Part No. Description MXP Series Ti11477 Parts MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 Parts MX Series Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator with Spud Assembly Rupture-to-Atmosphere Indicator1175 Cycle IndicatorsRupture Discs Singling and Crossporting Bar AssembliesCycle Switches Cycle Counters Part NoPart Numbers Description Type Part Number Pins Seal Proximity Cycle SwitchesConnection Cables for Proximity Switch Connection CablesGraco Information Graco Standard Warranty