Graco 312497F important safety instructions Lube Point Secondary Master Disconnect Hand Pump

Page 11

Repair

Section 4: Purging Air After Adding or Replacing a Master Divider Valve Module

LUBE POINT

SECONDARY

MASTER

DISCONNECT

HAND PUMP

BLEED

HERE

 

LINE

 

 

 

NEW VALVE

BLOCK

TI11116

FIG. 9

Steps 1-7, refer to FIG. 9.

1.Install the new or replacement module into the mas- ter divider valve assembly. Also connect the tubing or hoses to the appropriate secondary divider valve(s) or lubrication point(s) if the new/replace- ment module is a base section.

2.Do not completely tighten the connection(s) at the secondary divider valve’s inlet or at lubrication points.

3.Disconnect and remove the line from the pump at the inlet of the master divider valve.

4.Attach a hand pump filled with clean, filtered lubri- cant to the inlet port on the master divider valve.

5.Operate the hand pump until air-free lubricant is observed flowing from each secondary valve’s lube inlet connector and/or each lubrication point’s con- nector.

6.Tighten the fitting at the secondary valve inlet or at the lubrication port while lubricant is still flowing.

7.Remove the hand pump and reconnect the system pump to the inlet of the master divider valve.

The system is now ready for operation.

312497F

11

Image 11
Contents Sections Maximum Pressure Lube PointsPressure kPSI Divider TypePressure Relief Procedure Divider Valves SetupComponent Identification Typical Divider Valve CombinationsFilling Secondary-to-Lube Point Lines Prefilling Lubricant Distributor LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Section Air purging after RepairTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Bleed Hose Here Lube Point Secondary Master Automatic Relief Indicator Performance IndicatorsReset Indicator with Memory Rupture Indicator4a. Master Divider Valve Equipped With Performance Indicator MSP/MH MXP MGO Torque Values *see , Assembly Torque ft-lbsSeparation Blockage Contamination BlockageParts Technical DataDimensions MD SeriesLbs oz 1.55 kg MJ SeriesParts MSP Series Crossport Plate Optional Parts MSP Series 312497F MHH Series Lube Outlet Inlet Typical Part No. Description MXP Series Ti11477 Parts MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 Parts MX Series Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator with Spud Assembly Rupture-to-Atmosphere Indicator1175 Cycle IndicatorsRupture Discs Singling and Crossporting Bar AssembliesPart Numbers Cycle SwitchesCycle Counters Part No Description Type Part Number Pins Seal Proximity Cycle SwitchesConnection Cables for Proximity Switch Connection CablesGraco Information Graco Standard Warranty