Repair
Section 5: Purging Air After Adding or Replacing a Secondary Divider Valve Module
BLEED HOSE
HERE
LUBE POINT
SECONDARY
MASTER
BLEED
HERE
NEW VALVE
BLOCK
REMOVE INDICATOR
OR PORT PLUG
HAND PUMP | TI11115 |
FIG. 10
Steps
1.Install the new or replacement module to the sec- ondary divider valve assembly. Also connect the tubing or hoses to the appropriate lubrication point if the new/replacement module is a base section.
2.Do not completely tighten the connection(s) at the lubrication point.
3.Remove the performance indicator or indicator port plug from the working valve section on the second- ary divider valve assembly corresponding to the out- let port and line connected to a particular lube point.
4.Attach a hand pump filled with clean, filtered lubri- cant to the port on the secondary divider valve that was opened in Step 3.
5.Operate the hand pump until
6.Tighten the fitting at the lube point while lubricant is still flowing.
7.Repeat Steps 3 - 6 for any additional lubrication points connected to the new module.
8.Remove the hand pump and reinstall the perfor- mance indicator or port plug removed in Step 3 into the secondary divider valve’s open port.
The system is now ready for operation.
12 | 312497F |