Graco 312497F important safety instructions Pressure Relief Procedure

Page 2

Warnings

Warnings

The following Warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and hazard symbols refer to procedure-specific risks. Refer back to these Warnings. Additional, product-specific warnings may be found throughout the body of this manual where appli- cable.

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

SKIN INJECTION HAZARD

High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

Do not point dispense valve at anyone or at any part of the body.

Do not put your hand over the end of the dispense nozzle.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Pressure Relief Procedure

Follow this Pressure Relief Procedure whenever you are instructed to relieve pressure or check or service equipment.

1.Verify pump feeding valve is stopped and discon- nected from, or locked out of it’s driver.

2.Using a wrench, slowly loosen inlet nut.

3.Then, using a wrench, slowly loosen each port nut.

2

312497F

Image 2
Contents Divider Type Maximum Pressure Lube PointsPressure kPSI SectionsPressure Relief Procedure Typical Divider Valve Combinations SetupComponent Identification Divider ValvesPrefilling Lubricant Distributor Lines Filling Secondary-to-Lube Point LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Repair Section Air purging afterTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Bleed Hose Here Lube Point Secondary Master Rupture Indicator Performance IndicatorsReset Indicator with Memory Automatic Relief Indicator4a. Master Divider Valve Equipped With Performance Indicator Torque Values *see , Assembly Torque ft-lbs MSP/MH MXP MGOContamination Blockage Separation BlockageMD Series Technical DataDimensions PartsMJ Series Lbs oz 1.55 kgParts MSP Series Crossport Plate Optional Parts MSP Series 312497F MHH Series Lube Outlet Inlet Typical Part No. Description MXP Series Ti11477 Parts MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 Parts MX Series Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator Rupture-to-Atmosphere Indicator with Spud AssemblySingling and Crossporting Bar Assemblies Cycle IndicatorsRupture Discs 1175Part Numbers Cycle SwitchesCycle Counters Part No Proximity Cycle Switches Description Type Part Number Pins SealProximity Switch Connection Cables Connection Cables forGraco Standard Warranty Graco Information