Fujitsu MB96300 manual LIN-UART 2 JP 36, 37, 38, 39, 40, 42, 43, Can interfaces JP 24, 26, 34

Page 21

 

 

 

SK-96370-144PMC-GDC User Guide

 

 

 

Chapter 3 Jumpers and Switches

3.9.2 LIN-UART 2 (JP: 36, 37, 38, 39, 40, 42, 43, 45)

 

 

 

 

 

 

Jumper

 

Setting

 

 

Description

JP37

 

1-2

 

 

SIN2 is connected to RS232 transceiver

(RXD)

2-3

 

 

SIN2 is connected to LIN transceiver

JP39

1-2

 

 

SOT2 is connected to RS232 transceiver

(TXD)

2-3

 

 

SOT2 is connected to LIN transceiver

JP40

 

1-2

 

 

X9 pin 2 is connected to RS232 transceiver

(RS232/LIN)

2-3

 

 

X9 pin 2 is connected to LIN transceiver

 

 

 

JP36

 

Closed

 

 

RTS and CTS of X9 are connected

(RTS-CTS)

 

Open

 

 

RTS and CTS of X9 are not connected

 

 

 

 

JP38

1-2

 

 

DTR signal (pin 6 of X9) is used as reset source

(DTR/RTS)

2-3

 

 

RTS signal (pin 7 of X9) is used as reset source

 

 

 

 

 

 

 

 

 

JP43

 

Closed

 

 

LIN transceiver for X5 is enabled

(LIN enable)

 

Open

 

 

LIN transceiver for X5 is disabled

 

 

 

 

JP45

 

Closed

 

 

LIN-UART2 is LIN Master

(LIN master)

 

Open

 

 

LIN-UART2 is LIN Slave

 

 

 

 

JP42

 

Closed

 

 

LIN bus (X9 pin 1) is powered by the board

(LIN Vbat)

 

Open

 

 

LIN bus (X9 pin 1) is not powered by the board

 

 

 

 

 

 

 

 

 

 

Table 3-8: UART2 Settings

3.10CAN interfaces (JP: 24, 26, 34, 35)

Two high-speed CAN-transceivers can be connected to the microcontroller’s CAN interfaces (CAN0 and CAN1).

 

Jumper

 

Setting

 

 

Description

 

 

JP24

 

Closed

 

 

RX0 is connected to CAN0 (X6)

 

 

(CAN0 RX)

 

 

 

 

 

 

 

 

 

 

 

 

JP26

 

Closed

 

 

TX0 is connected to CAN0 (X6)

 

 

(CAN0 TX)

 

 

 

 

 

 

 

 

 

 

 

 

JP34

 

Closed

 

 

RX1 is connected to CAN1 (X8)

 

 

(CAN1 RX)

 

 

 

 

 

 

 

 

 

 

 

 

JP35

 

Closed

 

 

TX1 is connected to CAN1 (X8)

 

 

(CAN1 TX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3-9: CAN Settings

© Fujitsu Microelectronics Europe GmbH

- 21 -

FMEMCU-UG-960014-10

Image 21
Contents MB96300 Series Revision History Date IssueNo Liability for Consequential Damages Warranty and DisclaimerContents Programming the Internal Flash Memory Abstract OverviewFeatures General Description 8 I2C Bus Emulator SystemEmulation System Installation Connection/Power-OnDo not use any other probe cable than MB2198-507-E only Jumper Description / Function Type Default Coordinates Default Jumper settings for MB96370 SeriesFlash / Lime Jumper SettingsJumper Location Default Jumper SettingsJumpers and Switches Operating Mode S1MCU Operating Mode Power Supply Configuration Power Supply S2, JP 8, 15, 16, 17JP8 McuvccJP1 Subclock JP 1JP2 JP2Alarm Comparator JP Analog Power Supply Voltage JP 11, 12, 13Alarm Comparator ADC SupplyUart Reset Reset Generation JP 33, 41, 46, 47Reset Connection RST MCUUser Buttons SW1, SW2, SW3, SW4, SW5, SW6 JP 3, 4, 5, 6 I2C pull-up resistor JP 9User Push Buttons UART0 Settings LIN / UartLIN-UART 0 JP 19, 21, 23, 25, 27, 28, 29 Can Settings UART2 SettingsLIN-UART 2 JP 36, 37, 38, 39, 40, 42, 43 Can interfaces JP 24, 26, 3411 Flash Configuration Jumpers 10 External Flash ConfigurationExternal Flash memory JP 49, 52 External Sram memory JP 50, 53Glrst Flrst12 Graphic Display Controller interface Power connector ConnectorsMCU pin header connectors X20A, X20B, X21, X22 LIN-UART connectors X5Can Connector Signals Can Connector X6Canl CanhUser LEDs/LCD USER-LEDs & optional LC-Display J1MD0 In-Circuit-Programming ConnectorRstx SIN3VCC Connector J7 Alarm Comparator Connector J2GND Connector J8 External Supply Voltage Vin J3Jumper Settings for Programming via Uart 0 Asynchronous ModeJumper Settings for Programming via Uart 2 Programming the internal Flash memoryReset optional Jumper Settings for reset signalFlash Programming Flash Programming Socket Synchronous ModeRelated Products AppendixHttp//mcu.emea.fujitsu.com Information in the WWWEvaluation Board Emulation Board China-RoHS regulationTable of hazardous substances name and concentration Recycling Gültig für EU-LänderValid for European Union Countries