Fujitsu MB96300 manual Glrst, Flrst, Graphic Display Controller interface

Page 23

SK-96370-144PMC-GDC User Guide

Chapter 3 Jumpers and Switches

3.13 Graphic Display Controller interface (JP: 54, 55, 56, 57, 58, 60, 85, 86)

The SK-96370-144PMC-GDC provides the external bus interface on the two connectors X10 and X11 in order to support Graphic Display Controller sub-boards, e.g.: CREMSON-STARTERKITLIME.

Take care of proper jumper settings, in case those external sub-boards will be connected. Some signals, like A22, CS2 and CS3, are shared with the on-board FLASH and SRAM memory (see also chapter 3.11 and 3.12).

JP54 Address line A24 is not supported by the microcontroller

JP55 Address line A25 is not supported by the microcontroller

JP56

Signal sharing of A22 and CS2 for FLASH and GDC

3

 

4

2

JP57

Chip selection for external sub board

 

 

JP58 1.8V power supply

JP60 Mains power supply

JP70, 71 The port P08_0 may be used e.g. to generate manual reset on the sub board.

 

Jumper

Setting

 

 

Description

 

JP54

Open

 

Address line A24 is floating

 

(A24)

 

 

 

 

Closed

 

 

Address line A24 is connected to GND

 

JP55

Open

 

Address line A25 is floating

 

(A25)

 

 

 

 

Closed

 

Address line A25 is connected to GND

 

JP56

2-4

 

 

Address line A22 is connected to the FLASH

 

(GDC/FLASH)

1-2

 

 

CS2 is connected to the connector (see jumper JP57), too

 

3-4

 

 

Address A22 of FLASH is connected to GND

 

 

 

 

 

 

 

 

 

 

 

JP57

1-2

 

 

Connect CS3 to the connector

 

(CS2/CS3)

 

 

 

 

 

2-3

 

 

Connect CS2 to the connector

 

 

 

 

 

 

JP58

Open

 

1.8V is not supplied to connector X11B

 

(1V8)

 

 

 

 

Closed

 

1.8V is supplied to connector X11B

 

JP60

Open

 

 

Mains is not connected to connector X11B

 

(Mains)

Closed

 

Mains is connected to X11B

 

 

 

 

 

 

JP70

Open

 

P08_0 is not connected to X11A_11A

 

(GLRST)

 

 

 

 

Closed

 

P08_0 is connected to X11A_11A

 

JP71

Open

 

P08_0 is not connected to X11A_12A

 

(FLRST)

 

 

 

 

Closed

 

P08_0 is connected to X11A_12A

 

 

 

 

 

 

Table 3-12: Graphic Display Controller interface

© Fujitsu Microelectronics Europe GmbH

- 23 -

FMEMCU-UG-960014-10

Image 23
Contents MB96300 Series Revision History Date IssueNo Liability for Consequential Damages Warranty and DisclaimerContents Programming the Internal Flash Memory Abstract OverviewFeatures General Description Emulation System 8 I2C BusEmulator System Do not use any other probe cable than MB2198-507-E only InstallationConnection/Power-On Jumper Description / Function Type Default Coordinates Default Jumper settings for MB96370 SeriesFlash / Lime Jumper SettingsJumper Location Default Jumper SettingsMCU Operating Mode Jumpers and SwitchesOperating Mode S1 Mcuvcc Power Supply S2, JP 8, 15, 16, 17Power Supply Configuration JP8JP2 Subclock JP 1JP1 JP2ADC Supply Analog Power Supply Voltage JP 11, 12, 13Alarm Comparator JP Alarm ComparatorRST MCU Reset Generation JP 33, 41, 46, 47Uart Reset Reset ConnectionUser Push Buttons User Buttons SW1, SW2, SW3, SW4, SW5, SW6 JP 3, 4, 5, 6I2C pull-up resistor JP 9 LIN-UART 0 JP 19, 21, 23, 25, 27, 28, 29 UART0 Settings LIN / Uart Can interfaces JP 24, 26, 34 UART2 SettingsCan Settings LIN-UART 2 JP 36, 37, 38, 39, 40, 42, 43External Sram memory JP 50, 53 10 External Flash Configuration11 Flash Configuration Jumpers External Flash memory JP 49, 5212 Graphic Display Controller interface GlrstFlrst LIN-UART connectors X5 ConnectorsPower connector MCU pin header connectors X20A, X20B, X21, X22Canh Can Connector X6Can Connector Signals CanlUser LEDs/LCD USER-LEDs & optional LC-Display J1SIN3 In-Circuit-Programming ConnectorMD0 RstxExternal Supply Voltage Vin J3 Alarm Comparator Connector J2VCC Connector J7 GND Connector J8Programming the internal Flash memory Asynchronous ModeJumper Settings for Programming via Uart 0 Jumper Settings for Programming via Uart 2Flash Programming Reset optionalJumper Settings for reset signal Flash Programming Socket Synchronous ModeRelated Products AppendixHttp//mcu.emea.fujitsu.com Information in the WWWEvaluation Board Emulation Board China-RoHS regulationTable of hazardous substances name and concentration Valid for European Union Countries RecyclingGültig für EU-Länder