Design Spot 575E™
Gobo Rotation Er
(Gobo Rotation wheel 1- error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main PCB). The Gobo Rotation wheel 1 is not located in the default position after the reset.
Rotation gobo Er
(Rotating gobo wheel 2- error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main PCB). The Rotating gobo wheel 2 is not located in the default position after the reset.
Gobo Rotation Er
(Gobo Rotation wheel 2- error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main PCB). The Gobo Rotation wheel 2 is not located in the default position after the reset.
Prism Rotation Er
(Prism Rotation-wheel error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main PCB). The Prism Rotation -wheel is not located in the default position after the reset.
Shutter, Strobe Er
(Shutter, Strobe-wheel error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Shutter, Strobe -wheel is not located in the default position after the reset.
Focus Er | |
(Focus error) This message will | appear after the reset of the fixture if the yoke’s |
©Elation Professional® | 44 |