Teac manual WR-DA7 setting, DA-98, 38 setting

Page 27

WR-DA7 setting

To use the WR-DA7 as a slave unit, set the SOURCE SELECT to ‘WCK IN’ in the INPUT SET window of the D-I/O Setup Section on the MASTER unit.

(For wordclock synchronization using the DA98’s connection slot, set the SOURCE SELECT to ‘SLOT1’ on the MASTER WR-DA7. Keep ‘WCK IN’ on the SLAVE unit.)

To establish communication between the tandem WR-DA7 units, set the PORT SELECT to ‘TO PC’ in the SERIAL I/O SETUP in the MIDI SETUP screen for both the MASTER and SLAVE units. Then set the baud rates to the same value.

To send and receive MIDI messages, set the PORT select of Gen.Rx and Gen.Tx to ‘MIDI’ in the MIDI SETUP screen. On the TANDEM SLAVE unit, set the SEND/RECEIVE of the various MIDI mes- sages to ‘THRU.’

For MMC set the MMC PORT to ‘MIDI’ in the MIDI SETUP window for the same MMC channels to be received on the BRC.

For MTC reception on the WR-DA7, set MTC PORT to ‘MIDI’ in the MIDI SETUP window of the TANDEM (MASTER) unit.

To display the MTC timecode, set the TIME BASE to ‘MTC’ in the EXECUTE window of AUTOMA- TION SETUP Window.

(To use the SMPTE timecode connect the WR-SMPTE option card, and set the TIME BASE to ‘SMPTE.’ in the EXECUTE window of AUTOMATION SETUP Window.)

DA-98, 38 setting

Since the DA-98 and 38 receive digital input data from the TDIF-1, press the DIGITAL IN switch on the control panel.

To set the machine ID numbers of the DA-98 and 38, ID: 1 is assigned to the DA-98. The machine ID numbers are set to 1, 2, 3, and 4 in the order of cable connections from SYNC OUT to SYNC IN.

Select the sampling rate of the DA-98 to INT 48k or INT 44.1k. The sampling rate of the DA-98 is automatically set off the tape thatfs being used.

Operation of the DA-38 is synchronized with the DA-98, as a slave unit for the DA-98. Therefore, when the ID is set for any value other than 1, the DA-38 is set to the wordclock from the PW-88S SYNC cable.

Press the CHASE switch of the DA-38 front panel with the machine IDs 2, 3, and 4 to select CHASE to ‘ON’ so that synchronization can be performed with the master DA-98.

While ALL INPUT is ON; no audio is played back. For playback ALL INPUT should be set at OFF.

28

Image 27
Contents Application Guide Version Trademarks Table of Contents Introduction WR-DA7 as wordclock slave Installing and using option cards with the WR-DA7Wordclock WR-DA7 as wordclock masterTimecode WordclockTandem connection Connections ADAT, BRCOFF, SW2 OFF DA-98, 88Midi Connection DAT with AES/EBU or S/PDIF I/ODigital timepiece Expansion Software Macintosh VersionMidi Page WR-DA7 setting Adat settingMethod of connection Adat System configuration-1Example of systems for Adat 3 units and BRC BRC setting System configuration-2 Method of connection BRC settingBRC as the wordclock master BRC setting BRC as the wordclock slave Adat ID2 System configuration-3Example of systems with 3 DA-88s DA-88 setting System configuration-4 Method of connection DA-98, 38 setting System configuration Example of systems for analog 16-track recorder 1 unit MTR Example of systems for Digital Video Recorder 1 unit Digital Video Recorder Example of systems for VTR 1 unit, Adat 1 unit, and BRC BRC setting VTR Example of systems for VTR 1 unit and DA-98 1 unit DA-98 settingPage System configuration-9 Connecting Procedures WR-DA7 SetupSystem Example of Pro Tools ADAT, BRC Setup Pro Tools SetupPro Tools System Configuration-10System Example of Midi Sequencer Performer Midi Sequencer Performer Setup System Configuration-11 Connecting Procedures WR-DA7 Setup WR-DA7 Slave WR-DA7 MasterWR-DA7 System Configuration-12System Example of Akai DR8 1 unit DR8 SetupDR8 System Configuration-13PC Macintosh Setup Expansion Software SetupConnection to MAX Macintosh expansion software System Configuration-14 Midi Timepiece A/V Setup Midi Sequencer Digital Performer Setup Macintosh SetupSystem Configuration-15 Tandem-Connection to MAX Macintosh expansion software Macintosh for Expansion Software Setup System Configuration-16 Connecting Procedures Macintosh for Midi Sequencer Setup Midi Sequencer Digital Performer Setup System Configuration-17