PLANNING YOUR INSTALLATION
FACTORY BUILT FIREPLACES | Factory Built Fireplace Installation |
(Not Approved In Canada) |
|
In the USA, this appliance is approved for installation |
|
into a listed factory built solid fuel burning fireplace (built |
|
to UL 127 or ULC S610 standards). The fireplace fire- |
|
box must accept the insert without modification other |
|
than removing bolted or screwed together pieces such |
|
as smoke shelf / deflectors, ash lips, screen or door |
|
tracks and damper assemblies, that must be reinstalled |
|
to restore the fireplace to its original operating condition |
|
if the insert is removed and not replaced. The removal |
|
of any part must not alter the integrity or outer shell of |
|
the |
|
Venting Requirements for factory built fireplace: |
|
The fireplace damper must be secured in the open po- |
|
sition. This appliance requires the use of a 6” (152 mm) |
|
diameter flex or rigid, UL1777 listed 2100° HT liner or |
|
equivalent. The liner must extend from the flue outlet of |
|
the appliance to termination. Do not face seal over fire- |
|
place chimney cooling air systems. Offsets can be han- |
|
dled with an offset adapter (it aligns starter pipe with |
|
fireplace flue). For more information on the offset |
|
adapter, see pages 10 and 26. |
|
|
|
WARNING: DO NOT SUBSTITUTE THE HEAT |
|
RATED 2100°HT LINER WITH ANY OTHER TYPE |
|
LINE OR A FIRE MAY RESULT CAUSING PROP- |
|
ERTY DAMAGE, PERSONAL INJURY OR LOSS |
|
OF LIFE. |
|
PAGE 6