Lennox Hearth 2800HT operation manual Masonry Fireplaces, Metal Tag

Page 7

PLANNING YOUR INSTALLATION

MASONRY FIREPLACES

This appliance is approved for installation into a ma- sonry fireplace built to UBC 37 or ULC S628 standards. Do not remove brick or mortar form the masonry fire- place to accommodate this appliance. If the fireplace has been modified to accommodate the fireplace insert, a metal tag documenting what was modified must be attached to the fireplace (as required by Clause 5.1.11 it must be secured using screws or nails to the fire- place, in a location readily visible should the fireplace insert be removed). The lettering shall not be less than 5 mm high.

Metal Tag

THIS FIREPLACE HAS BEEN ALTERED TO AC- COMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PER- SON PRIOR TO RE-USE AS A CONVENTIONAL FIREPLACE

IMPORTANT: Any opening between the masonry of the fireplace and the facing masonry must be per- manently sealed.

USA Requirements / Masonry Fireplaces - The fire- place damper must be secured in the open position. In the USA, a flue extension past the fireplace header is required as a minimum. A preferred installation is a positive flue connection (sealing the throat of the chim- ney). This appliance requires the use of a 6” (152 mm) diameter flex or rigid single wall pipe, minimum 24 / 25 MSG black or blued steel connector pipe (stainless steel recommended).

Canada Requirements / Masonry Fireplaces - – This fireplace insert must be installed into an approved solid fuel Masonry fireplace only (installation into a factory built fireplace is not approved). The fireplace damper must be secured in the open position. The fireplace in- sert must be installed with a continuous chimney liner of 6” / 152 mm diameter extending from the fireplace in- sert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of CAN / ULC – S635, Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents, or CAN / ULC – S640 Standard for Lining Systems for New Masonry Chimneys.

Offsets

Offsets can be handled with an offset adapter (it aligns starter pipe with fireplace flue). For more information on the offset adapter, see pages 10 and 26.

FIREPLACE CHIMNEY MAXIMUM SIZE TO ENSURE PROPER DRAFT – USA ONLY

Note: Installations in Canada require a full length liner. The fireplace insert flue size is 6 inches (152 mm) di- ameter, which is approximately 28 square inches (711 square mm), the minimum. The maximum flue size should be no more than (3) three times the cross sec- tional area of the size of the fireplace insert flue collar. In this case, that would be no larger than a 10 inch (254

mm)diameter stack (area = approx. 85 sq. inches [216 sq. cm]).

Note: Formulas for calculating Area:

Calculating area of a circle:

πx r2 = Area (π = 3.1416, r = 1/2 diameter)

To calculate area of square or rectangle:

Width x Depth = Area

Notes:

It may be necessary to use a full-length liner to achieve adequate draft for the appliance. A draft gauge should read more than .04 W.C.I, but less than

.08 W.C.I. for optimum performance.

This appliance is approved for all heatform style fireplaces (masonry fireplace with a metal fire- box liner).

PAGE 7

Image 7
Contents 775004M, Rev. J, 11/03 Installation and Operation ManualImportant Warnings Table of Contents Chimney Inspection Planning Your Installation Smoke Detectors Hearth ProtectionDraft Requirements ClearancesProvide Adequate AIR for Combustion Venting Requirements for factory built fireplace Factory Built Fireplace InstallationFactory Built Fireplaces Not Approved In CanadaMetal Tag Masonry FireplacesInstallation Marble Power Cord ChangeoverInstallation Steps Baffle PlateWrong CorrectSurround Assembly Primary AIR Control Product Features and ControlsPositive Flue Connection for Masonry Blower SystemCare and Operation Refueling HOW to Start and Maintain a FireAIR Draft Controls Start-Up Air ControlWiring Diagram Power Flow Diagram Fuel MaintenanceRemoval of Fireplace Insert for Inspection Cleaning BlowersServicing Glass Replacing GlassReinstall Baffle Plate Cleaning / Removing Baffle Plate To remove, locateTroubleshooting Overfiring Damage BTU Dimensions shown are approximations only +/- ¼ 6.4 mm63% Gph Lbs kg Manual Cfm total Description Replacement Parts List Model 2800HTReplacement Parts List Model 2800HT Component Diagrams Model 2800HT Zero Clearance Kit SAFETY/LISTING LabelOffset Adapter Actual Appearance Masonry Fireplace KitSAFETY/LISTING Label EPA Label Ownership Records Service and Maintenance LOGWest Taft Avenue Orange, CA