INSTALLATION
10.Offsets can be handled using an offset adapter (it aligns starter pipe with flue. See Offset Adapter, page 26 for ordering information). Do not push insert in completely until surround assembly is installed. Care should be used to ensure that this adjustable connector is oriented so it does not angle downhill when positioned on the flue outlet on top of insert.
CORRECT
CORRECT – Level or even. Slightly up at the outbound end is better.
12.Reaching over the top of the insert, install the starter pipe in the stove flue, or attach the positive flue con- nection to the insert. See * Note, page 11.
WRONG
WRONG – This may produce a problem of smoking during refueling, or poor chimney draw.
11.If the floor of the fireplace is lower than the hearth, leveling bolts will need to be installed (not included with the hardware. Use a 3/8” (10 mm) bolt with 2 nuts). The bolt length should be at least 1” (25.4 mm) longer than needed. Locate the leveling bolt brackets on the sides of the insert in the back. Install the 2 leveling bolts with nuts and adjust length as needed.