8.1.6.Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
•Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control | — | — | O | O | O | O | O | — | — | — |
Tab (rpm) | PSHI | SHI | Hi | Me+ | Me | Me- | Lo | Lo- | SLo | SSLo |
|
|
|
|
|
|
|
|
|
|
|
E15D | 600 | 560 | 560 | 495 | 480 | 425 | 400 | 370 | 310 | 200 |
E18D | 680 | 640 | 590 | 563 | 510 | 488 | 430 | 410 | 350 | 200 |
E21D | 800 | 750 | 700 | 660 | 600 | 560 | 510 | 480 | 410 | 200 |
|
|
|
|
|
|
|
|
|
|
|
[Heating]
Remote Control | — | — | O | O | O | O | O | — | — | — |
Tab (rpm) | PSHi | SSHi | SHi | Me+ | Me | Me- | Lo | Lo- | SLo | SSLo |
E15D | 650 | 610 | 600 | 545 | 540 | 495 | 480 | 440 | 300 | 200 |
E18D | 740 | 690 | 640 | 618 | 560 | 553 | 490 | 490 | 320 | 200 |
|
|
|
|
|
|
|
|
|
|
|
E21D | 870 | 820 | 770 | 745 | 670 | 655 | 580 | 570 | 370 | 200 |
B. Indoor Fan Control
i. Indoor fan control operation outline
1. Cooling / Dry
20