CHANGING THE REMOTE CONTROL TRANSMISSION

CODE

1.Press AUTO SW continuously for 11 seconds (buzzer sound = pep pep pep)

2.After 11 seconds, release AUTO SW, then press Remo- Con TIMER “” SW continuously for 5 seconds. Reset code will be transmitted. After the reset code is transmitted, release TIMER “” SW.

3.Press Remo-Con “OFF/ON” button. The new Remo-Con No. will be accepted and memorized, after which the new Remo-Con No. can be used.

REMO-CON NO. CHANGE IN REMOTE CONTROL

1.Remove the batteries from the battery compartment of the Remote Control.

2.On the left side of the battery compartment, there is a small opening in the centre in which Jumper (J_A) can be seen. In the accepted Remo-Con PCB shown beside, Jumper (J_B) can be seen.

J_A

J_B

Remo-Con No.

Short

Open

A (Default)

 

 

 

Open

Open

B

 

 

 

Short

Short

C

Open

Short

D

 

 

 

CHECK ITEMS

Is there any gas leakage at flare nut connections?

Has the heat insulation been carried out at flare nut connections?

Is the cooling operation normal?

Is the indoor unit property secured to the installation plate?

Is the power supply voltage complied with rated value?

Is the connecting cable being fixed to the terminal board firmly?

Is the connecting cable being clamped firmly?

Is the drainage OK?

Is the Earth wire connection properly done?

Is there any abnormal sound?

Is the thermostat operation normal?

Is the remote control’s LCD operation normal?

HAND OVER

Teach the customer the operation and maintenance procedures, using the operation manual (air filter cleaning, temperature control, etc.)

As to parts to be sold separately

With regards to installation of the parts sold separately, follow the installation manual which is provided with the parts sold separately.

65

Image 65
Contents Contents Serviceability Improvement FeaturesProduct Environmental ProtectionFunctions Remote ControlIndoor Unit Automatic Operation SwitchOutdoor Unit CS-E15DB4EW CU-E15DBE Product SpecificationsFPI CS-E18DB4EW CU-E18DBE CS-E18DB4EW CU-E18DBENet Weight Lb kg CS-E21DB4ES CU-E21DBE CS-E21DB4ES CU-E21DBE108 CS-E15DB4EW CS-E18DB4EW CS-E21DB4ES DimensionsIndoor Unit & Remote Control CU-E15DBE CU-E18DBE CU-E21DBE Refrigeration Cycle Diagram Block Diagram Wiring Diagram Basic Operation Temperature Shifting FlowOperation Details Heating Operation Thermostat control Cooling Operation Thermostat controlSoft Dry Operation Thermostat control Automatic Operation Indoor Fan Control Indoor Fan Motor OperationBasic Rotation Speed rpm Heating Ii. Auto Fan Speed Cooling Fan Motor Control Deodorizing Control Outdoor Fan Motor OperationAirflow Direction Quiet operation Cooling Mode/Cooling area of Dry ModeVertical Airflow PurposeQuiet operation Heating Control contentsHour Real Time Timer Control Powerful Mode OperationOn Timer OFF TimerAuto Restart Control Drain Pump ErrorIndication Panel Drain Pump Control OperationIPM Power transistor Prevention Control Protection Control FeaturesSeconds Forced Operation Total Running Current ControlLow Pressure Prevention Control Gas Leakage Detection Compressor Overheating Prevention ControlLow Frequency Protection Control Control start conditionsCooling Overload Control Anti-Dew Formation Control Anti-Freezing ControlOverload Protection Control Deice Control Operating Instructions Page Page Page Page Page Page Page About R410A Refrigerant Installation And Servicing Air Conditioner Using R410AOutline Necessary Tools Tools For Installing/Servicing Refrigerant PipingTorque wrenches 10.2.2. R410A ToolsSensitivity with R410A is about 23 g/year Electronic scale for refrigerant charging 10.2.3. R410A Tools Which Are Usable for R22 ModelsPiping Materials Processing and Connecting Piping MaterialsRefrigerant Piping Work Storing and Managing Piping Materials Precautions Installation, Transferring, ServicingAC Units Replacement Using Existing Refrigerant Piping Transferring Using New Refrigerant PipingRecharging Refrigerant During Servicing PrecautionBrazing Method for Preventing Oxidation BrazingServicing Tips Safety Precautions Installation InstructionsPage Outdoor Unit Attached accessoriesSelect the best location Page Installation of Indoor Unit Vacuum drying Indoor Unit Drain PipingWall seal Heat InsulationConnecting the Cable to the Indoor Page Connecting The Piping To Outdoor Unit Connecting The Piping To Indoor UnitRefer to Select the best location section Cutting and Flaring the PipingEvacuation of the Equipment Disposal of Outdoor Unit Drain Water Auto Switch OperationREMO-CON NO. Change in Remote Control Changing the Remote Control Transmission CodeCheck Items Hand OverRated Frequency Operation TroubleshootingServicing Information Troubleshooting Air Conditioner Refrigeration cycle system Breakdown Self Diagnosis Function Judgement Error Codes TableSetting Remote Control Transmission Code Remote Control ResetAuto OFF/ON Button Disassembly of Parts Page Remove the top panel and front panel Outdoor Electronic Controller Removal ProcedureCS-E15DB4EW CU-E15DBE Technical DataOperation Characteristics CS-E18DB4EW CU-E18DBE CS-E21DB4ES CU-E21DBE CS-E15DB4EW CU-E15DBE Sensible Capacity ChartCS-E18DB4EW CU-E18DBE CS-E21DB4ES CU-E21DBECS-E15DB4EW CS-E18DB4EW CS-E21DB4ES Exploded View Indoor UnitPage CZ-BT20E Front Grille Complete Replacement Parts List Indoor Unit REF. no Part Description QTY Front Grille Complete CU-E15DBE CU-E18DBE CU-E21DBE Exploded View Outdoor UnitReplacement Parts List Outdoor Unit CS-E15DB4EW CS-E18DB4EW CS-E21DB4ES Schematic Diagram 1/4 Electronic Circuit DiagramR17 Schematic Diagram 2/4SSR02 SSR01 Schematic Diagram 3/4WHT Schematic Diagram 4/4CU-E15DBE CU-E18DBE CU-E21DBE Schematic Diagram 1/4 FUSE2 IC1 Yellow Schematic DiagramTimer Table Outdoor How to use electronic circuit diagramTimer Table Indoor Remote Control Print Pattern Indoor Unit Printed Circuit Board Print Pattern Outdoor Unit Printed Circuit Board View

CS-E15DB4EW specifications

The Philips CS-E15DB4EW is an exceptional air conditioner that exemplifies modern cooling technology while emphasizing energy efficiency and user comfort. This model is designed to provide reliable performance in various settings, making it suitable for both residential and light commercial applications.

One of the standout features of the Philips CS-E15DB4EW is its powerful cooling capacity. With a cooling power reaching up to 15000 BTUs, this air conditioner is capable of effectively cooling medium to large-sized rooms. This high capacity ensures that users enjoy a refreshingly cool environment, even during the hottest summer months.

Energy efficiency is a prominent characteristic of the CS-E15DB4EW. It features an advanced inverter technology that optimizes power consumption while maintaining the desired temperature. This technology not only results in lower electricity bills but also reduces environmental impact by minimizing energy waste. The air conditioner boasts a high EER (Energy Efficiency Ratio), making it a responsible choice for energy-conscious consumers.

In terms of convenience, the CS-E15DB4EW is equipped with a user-friendly remote control, allowing users to adjust settings from a distance. This includes temperature adjustments, fan speed settings, and timer functions, providing flexibility and comfort at the users' fingertips. Additionally, the air conditioner features various operating modes, including cool, dry, and fan modes, catering to diverse climatic conditions and individual preferences.

Another remarkable characteristic of the Philips CS-E15DB4EW is its quiet operation. With a noise level as low as 30 dB, this unit ensures that users can enjoy a peaceful environment without the disruptive sounds typical of standard air conditioning units. This feature is particularly beneficial for bedrooms or study areas where concentration or relaxation is crucial.

Moreover, the unit is designed with a sleek, modern aesthetic that seamlessly integrates into any interior decor. The easy-to-clean filters and compact design contribute to its practicality, allowing for efficient maintenance and longevity.

In conclusion, the Philips CS-E15DB4EW stands out as a versatile, efficient, and user-friendly air conditioning solution. With its powerful cooling capacity, energy-saving technologies, convenient features, and quiet operation, it effectively addresses the cooling needs of various environments. Whether for residential use or light commercial applications, this model is designed to provide a comfortable atmosphere while being mindful of energy consumption and environmental impact.