Philips CS-E15DB4EW specifications

Page 56

CS-E15DB4EW CU-E15DBE / CS-E18DB4EW CU-E18DBE / CS-E21DB4ES CU-E21DBE

* If the height from the floor to ceiling exceeds three meters, air flow distribution deteriorates and the effect is decreased.

WARNING

4.The installation position must be able to support a load four times the indoor unit weight.

5.The indoor unit must be away from heat and steam sources, but avoid installing it near an entrance.

6.The indoor unit must allow easy draining.

7.The indoor unit must allow easy connection to the outdoor unit.

8.Place the indoor unit according to the height from the ceiling shown in the illustration below.

9.The indoor unit must be from at least 3m away from any noise-generating equipment. The electrical wiring must be shielded with a steel conduit.

10.If the power supply is subject to noise generation, add a suppressor.

11.Do not install the indoor unit in a laundry. Electric shocks may result.

NOTE

Thoroughly study the following installation locations

1.In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the turbo fan, the fin of the heat exchanger and the drain pump, resulting in heat exchange reduction, spraying, dispersing of water drops, drain pump malfunction, etc.

In these cases, take the following actions:

Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily steam which should not flow into the suction of the air conditioner.

Make enough distance from the cooking room to install the air conditioner in such place where it may not suck in oily steam.

2.Avoid installing the air conditioner in such circumstances where cutting oil mist or iron powder exist especially in factories, etc.

3.Avoid places where inflammable gas is generated, flows-in, contaminated, or leaked.

4.Avoid places where sulphurous acid gas or corrosive gas can be generated.

5.Avoid places near high frequency generators.

Model Name

Height in the ceiling

CS-E15DB4**

 

CS-E21DB4**

280 mm or more

CS-E18DB4**

 

56

Image 56
Contents Contents Features Serviceability ImprovementProduct Environmental ProtectionRemote Control FunctionsAutomatic Operation Switch Indoor UnitOutdoor Unit Product Specifications CS-E15DB4EW CU-E15DBEFPI CS-E18DB4EW CU-E18DBE CS-E18DB4EW CU-E18DBENet Weight Lb kg CS-E21DB4ES CU-E21DBE CS-E21DB4ES CU-E21DBE108 CS-E15DB4EW CS-E18DB4EW CS-E21DB4ES DimensionsIndoor Unit & Remote Control CU-E15DBE CU-E18DBE CU-E21DBE Refrigeration Cycle Diagram Block Diagram Wiring Diagram Basic Operation Temperature Shifting FlowOperation Details Heating Operation Thermostat control Cooling Operation Thermostat controlSoft Dry Operation Thermostat control Automatic Operation Indoor Fan Control Indoor Fan Motor OperationBasic Rotation Speed rpm Heating Ii. Auto Fan Speed Cooling Fan Motor Control Outdoor Fan Motor Operation Deodorizing ControlQuiet operation Cooling Mode/Cooling area of Dry Mode Airflow DirectionVertical Airflow PurposeControl contents Quiet operation HeatingPowerful Mode Operation Hour Real Time Timer ControlOn Timer OFF TimerDrain Pump Error Auto Restart ControlIndication Panel Drain Pump Control OperationProtection Control Features IPM Power transistor Prevention ControlSeconds Forced Operation Total Running Current ControlCompressor Overheating Prevention Control Low Pressure Prevention Control Gas Leakage DetectionLow Frequency Protection Control Control start conditionsCooling Overload Control Anti-Freezing Control Anti-Dew Formation ControlOverload Protection Control Deice Control Operating Instructions Page Page Page Page Page Page Page About R410A Refrigerant Installation And Servicing Air Conditioner Using R410AOutline Tools For Installing/Servicing Refrigerant Piping Necessary Tools10.2.2. R410A Tools Torque wrenchesSensitivity with R410A is about 23 g/year 10.2.3. R410A Tools Which Are Usable for R22 Models Electronic scale for refrigerant chargingPiping Materials Processing and Connecting Piping MaterialsRefrigerant Piping Work Storing and Managing Piping Materials Installation, Transferring, Servicing PrecautionsTransferring Using New Refrigerant Piping AC Units Replacement Using Existing Refrigerant PipingPrecaution Recharging Refrigerant During ServicingBrazing Method for Preventing Oxidation BrazingServicing Tips Installation Instructions Safety PrecautionsPage Outdoor Unit Attached accessoriesSelect the best location Page Installation of Indoor Unit Indoor Unit Drain Piping Vacuum dryingHeat Insulation Wall sealConnecting the Cable to the Indoor Page Connecting The Piping To Indoor Unit Connecting The Piping To Outdoor UnitRefer to Select the best location section Cutting and Flaring the PipingEvacuation of the Equipment Auto Switch Operation Disposal of Outdoor Unit Drain WaterChanging the Remote Control Transmission Code REMO-CON NO. Change in Remote ControlCheck Items Hand OverRated Frequency Operation TroubleshootingServicing Information Troubleshooting Air Conditioner Refrigeration cycle system Breakdown Self Diagnosis Function Error Codes Table JudgementRemote Control Reset Setting Remote Control Transmission CodeAuto OFF/ON Button Disassembly of Parts Page Outdoor Electronic Controller Removal Procedure Remove the top panel and front panelCS-E15DB4EW CU-E15DBE Technical DataOperation Characteristics CS-E18DB4EW CU-E18DBE CS-E21DB4ES CU-E21DBE Sensible Capacity Chart CS-E15DB4EW CU-E15DBECS-E18DB4EW CU-E18DBE CS-E21DB4ES CU-E21DBEExploded View Indoor Unit CS-E15DB4EW CS-E18DB4EW CS-E21DB4ESPage CZ-BT20E Front Grille Complete Replacement Parts List Indoor Unit REF. no Part Description QTY Front Grille Complete Exploded View Outdoor Unit CU-E15DBE CU-E18DBE CU-E21DBEReplacement Parts List Outdoor Unit Electronic Circuit Diagram CS-E15DB4EW CS-E18DB4EW CS-E21DB4ES Schematic Diagram 1/4Schematic Diagram 2/4 R17Schematic Diagram 3/4 SSR02 SSR01Schematic Diagram 4/4 WHTCU-E15DBE CU-E18DBE CU-E21DBE Schematic Diagram 1/4 FUSE2 IC1 Schematic Diagram YellowTimer Table Outdoor How to use electronic circuit diagramTimer Table Indoor Remote Control Print Pattern Indoor Unit Printed Circuit Board Print Pattern Outdoor Unit Printed Circuit Board View

CS-E15DB4EW specifications

The Philips CS-E15DB4EW is an exceptional air conditioner that exemplifies modern cooling technology while emphasizing energy efficiency and user comfort. This model is designed to provide reliable performance in various settings, making it suitable for both residential and light commercial applications.

One of the standout features of the Philips CS-E15DB4EW is its powerful cooling capacity. With a cooling power reaching up to 15000 BTUs, this air conditioner is capable of effectively cooling medium to large-sized rooms. This high capacity ensures that users enjoy a refreshingly cool environment, even during the hottest summer months.

Energy efficiency is a prominent characteristic of the CS-E15DB4EW. It features an advanced inverter technology that optimizes power consumption while maintaining the desired temperature. This technology not only results in lower electricity bills but also reduces environmental impact by minimizing energy waste. The air conditioner boasts a high EER (Energy Efficiency Ratio), making it a responsible choice for energy-conscious consumers.

In terms of convenience, the CS-E15DB4EW is equipped with a user-friendly remote control, allowing users to adjust settings from a distance. This includes temperature adjustments, fan speed settings, and timer functions, providing flexibility and comfort at the users' fingertips. Additionally, the air conditioner features various operating modes, including cool, dry, and fan modes, catering to diverse climatic conditions and individual preferences.

Another remarkable characteristic of the Philips CS-E15DB4EW is its quiet operation. With a noise level as low as 30 dB, this unit ensures that users can enjoy a peaceful environment without the disruptive sounds typical of standard air conditioning units. This feature is particularly beneficial for bedrooms or study areas where concentration or relaxation is crucial.

Moreover, the unit is designed with a sleek, modern aesthetic that seamlessly integrates into any interior decor. The easy-to-clean filters and compact design contribute to its practicality, allowing for efficient maintenance and longevity.

In conclusion, the Philips CS-E15DB4EW stands out as a versatile, efficient, and user-friendly air conditioning solution. With its powerful cooling capacity, energy-saving technologies, convenient features, and quiet operation, it effectively addresses the cooling needs of various environments. Whether for residential use or light commercial applications, this model is designed to provide a comfortable atmosphere while being mindful of energy consumption and environmental impact.