AUXILIARY CONTROL

Figure below illustrates the auxiliary control on the fan coil. This can be used to operate / control the air conditioner when the remote controller is not available or lost.

Test

Use to operate the air conditioner under "COOL" mode. All other functions will not be effective. The air conditioner will automatically stop operating after 30 minutes. This is to test if the air conditioner is in working condition.

Remote

In this position, the air conditioner is controlled by the remote controller.

Auto

Use to by-pass the remote controller. The air conditioner will operate automatically when power is supplied. The remote controller is ineffective in this position.

Red indicating lamp

Red light will be lit when electrical power is supplied to the air conditioner.

Green indicating lamp

This green lamp will be lit when the compressor starts operating. It indicates cooling operation is in progress. It will blink if the operating temperature is abnormal.

Image 14
Contents AMW / AMC Series Safety Considerations Tools and SuppliesOutdoor Unit Selection of LocationIndoor Unit Installation Method Recommended Height and LengthMounting Installation Plate Installation of FAN Coil Mounting Condensing UnitRefrigeration Piping & Drainage Preparation of PipingFlare Fitting CONNECTION. There are 3 piping rules Precautions When Bending PipesPiping Insulation Condensing Units Precautions When Connecting PipesFan Coil AIR Purging Drain Pipe Connection SlimeLocation of Terminal Block Electrical WiringWiring Connection External Finishing of PipingOperating Tips Product DescriptionAuxiliary Control Model AMW 25 Remote Control OperationControls and Indicators Model AMW 45 Operating Instructions Operating Guide Model AMW 25Functions Care and Maintenance END of SeasonCooling is insufficient Trouble ShootingAir conditioner does not operate AMW/AMC AMW/AMC AMW/AMC 45 Service Notes