GE X-9 Program EQ Q, Values, Meter release time, Meter peak hold, Time, Digital out, Curve

Page 19

 

 

 

 

5 Menus

 

 

 

 

 

 

 

Function

Menu

Meaning

Available settings

Notes

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Program EQ Q

11_E

Sets the Q value for the

After pressing ENTER to

Use the left menu sys-

 

values

 

EQ bands of the

select the menu, use the dial to

tem for programs 1 and

 

 

 

selected program (see

select the band (H=high,

3.

 

 

 

“EQ Q setting” on

M*=mid, L=low) and press

Use the right menu sys-

 

 

 

page 28)

ENTER.

tem for programs 2 and

 

 

 

 

A low value of Q

4.

 

 

 

 

nOr Normal value of Q

 

 

 

 

 

B high value of Q

 

 

 

 

 

Value changes as selection is

 

 

 

 

 

made. Press ENTER to con-

 

 

 

 

 

firm.

 

 

 

 

 

 

 

 

Meter release time

12Mr

Sets the meter release

nor* Normal

Can be performed on

 

 

 

time (see “Adjusting the

SLO Slow

both left and right menu

 

 

 

output volume” on

 

systems.

 

 

 

page 16).

 

 

 

 

 

 

 

 

 

Meter peak hold

13MP

Sets the meter peak

All values are in seconds

Can be performed on

 

time

 

hold time (“Adjusting the

OFF

both left and right menu

 

 

 

output volume” on

05.

systems.

 

 

 

page 16)

10. *

 

 

 

 

 

20.

 

 

 

 

 

 

 

 

Digital out

14dI

Sets whether the signal

nOr* Post-fader signal

Can be performed on

 

 

 

from the digital output is

rEc Pre-fader signal

both left and right menu

 

 

 

pre- or post master

 

systems.

 

 

 

fader

 

 

 

 

 

 

 

 

 

Program fader

15Fc

Sets the fader curve as

After pressing ENTER to

Can be performed on

 

curve

 

described and shown in

select the menu, use the dial to

both left and right menu

 

 

 

“Program fader “curve””

select the program fader to be

systems.

 

 

 

on page 21.

set (1, 2, 3 or 4) and press

 

 

 

 

 

ENTER.

 

 

 

 

 

Select from the following:

 

 

 

 

 

A1 –6 dB

 

 

 

 

 

nOr* –12 dB

 

 

 

 

 

A2 –24 dB

 

 

 

 

 

Press ENTER to confirm.

 

 

 

 

 

 

 

 

Program fader

16Fr

Sets the fader direction

After pressing ENTER to

Can be performed on

 

reverse

 

to reverse as described

select the menu, use the dial to

both left and right menu

 

 

 

in “Program fader direc-

select the program fader to be

systems.

 

 

 

tion” on page 21.

set (1, 2, 3 or 4) and press

 

 

 

 

 

ENTER.

 

 

 

 

 

Select:

 

 

 

 

 

NOr* Normal

 

 

 

 

 

rEV Reverse

 

 

 

 

 

Press ENTER to confirm.

 

 

 

 

 

 

 

 

Sampler tempo

17St

Sets the sampler play-

After pressing ENTER to

Can be performed on

 

 

 

back pitch for either

select the menu, use the dial to

both left and right menu

 

 

 

sampler 1 or sampler 2.

select the sampler to be set

systems.

 

 

 

 

(S1*, or S2) and press

When sampler data is

 

 

 

 

ENTER.

erased, the value is

 

 

 

 

Use the dial to select the value

reset to 0%.

 

 

 

 

(from -100to100) and press

 

 

 

 

 

ENTER to confirm.

 

 

 

 

 

 

 

 

TASCAM X-9Owner’s Manual 19

Image 19
Contents Professional Digital DJ Mixer Important Safety Precautions Important Safety Instructions Table of Contents Environmental considerations Some notes and precautionsIntroduction Serial number, etcRoad map to front panel functions Getting acquainted withProgram gain level, EQ and assignment section Microphone control Sampler sectionCue selection keys and monitor keys Program faders Master faderExternal effect Effect, menu, etc. management Cross-fader and fader controlsDigital connections ConnectionsRecord turntables CD decks, etcMicrophone connection and use Booth outputsFader start/stop connections Headphones connecting and usingFootswitches External effects unitTo use the external effects unit External effectsAssigning sources to programs Learning moreAbout programs Cross-fadingSignal flow Playing a song Adjusting the output volumeCue previewing sounds Menu reference How the X-9 shows charactersMenus Meter peak hold Program EQ QValues Meter release timeProgram 1 balance Restore factoryPresets Mic balanceFader start FadersProgram fader curve Program fader directionCross-fader start Cross-fader curveCross-fader reverse Beat parameter EffectsSelecting the effect type Editing the effectsLPFa Effect parametersStoring effects Recalling stored effect settings Recording a sample SamplersPlaying back samples Erasing samples Editing samplesSample pitch Viewing EQ settings EQ Q settingCutting the EQ bands Remembering and recalling EQ settings Control I/O Specifications, etcSpecifications Audio I/OGeneral specifications Audio specificationsDimensional drawing Case mounting Mounting the X-9 in a rackEtc Block diagramPage Teac Corporation