DigiTech Comprehensive Guide to Utilizing Your RP21D Musical Instrument

Page 63

RP21D User’s Guide Section Four - Utilities

 

2

UsrDflt:Preamp

User 1

 

 

 

%kHz

 

 

%kHz

 

%kHz

 

 

 

 

 

 

 

 

1

 

2

3

4

 

Yes￿msdB

---msdB

msdB

 

U 1

 

LINK CHANGED

 

LINK CHANGED

LINK CHANGED

 

LINK CHANGED

 

 

 

COMP WAH

TUBE EQ

GATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L/R OUTS

FACTORY USER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

 

 

 

 

 

 

 

 

BANK

9 OF 15 b

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Press the number two button and rotate the Data Wheel to select the Effect Module whose Default you want to dump.

3.Press the number four button and rotate the Data Wheel to select the User Default you want to dump.

4.To initiate the dump, press the number one button and rotate the Data Wheel. The Display briefly reads “ Sending User Default.” It will then return to the User Default Dump Page.

Assigning a MIDI CC to Pedals

This function allows you to send MIDI Continuous Controller (CC) information out the MIDI port while the footswitch still maintains its ability to control a parameter within the RP21D. When assigned to a footswitch, the switch will toggle between CC values 0 or 127. CC numbers 0 through 127 are available. This function is only available for footswitches that have been programmed to toggle effects on and off within the RP21D. To assign the MIDI CC number which will be transmitted from the applicable footswitches, do the following:

1. Press the Utility button once, then use the Next or Previous Page buttons until you reach page 10 of the utility menu. The Display reads:

 

 

 

 

 

 

 

￿￿

2

Pdls:Banks FS=Prg CCTran

1

2

￿ 1

 

3

1

4 ---

LINK CHANGED

LINK CHANGED

 

LINK

CHANGED

LINK CHANGED

 

COMP WAH

TUBE

EQ GATE

L/R OUTS

FACTORY USER

 

 

DIST

EQ

#DIGITAL

 

 

 

 

 

 

PAGE 10OF15 b

 

 

 

 

 

 

 

 

 

CLIP

 

L/R OUTS

2.Press the number two button and turn the Data Wheel to select the Bank which will be used to transmit the CC commands.

3.Press the number three button and turn the Data Wheel to select the footswitch that you wish to assign a CC number to.

4.Press the number four button and turn the Data Wheel to select the CC number you wish to transmit from the footswitch.

Assigning a MIDI CC to the Expression Pedal

The Expression Pedal can act as a MIDI continuous controller for external MIDI devices which you have connected to the MIDI out port of the RP21D. You can select any MIDI CC number between 0 and 127 that you want to transmit CC information on. The procedure for assigning a MIDI CC number to the Expression Pedal is as follows:

1. Press the Utility button once. Use the Next or Previous Page buttons until you reach page 11 of the utility menu. The Display reads:

Expression Send:￿￿ CC#

2

1

2

￿ 1

 

3

1

4 OFF

LINK CHANGED

LINK CHANGED

 

LINK

CHANGED

LINK CHANGED

 

COMP WAH

TUBE

EQ GATE

L/R OUTS

FACTORY USER

 

 

DIST

EQ

#DIGITAL

 

PAGE 11OF15 b

 

 

 

 

 

 

 

 

 

CLIP

 

L/R OUTS

2. Press the number four button and turn the Data Wheel to select the CC number that you wish to transmit from the Expression Pedal.

58

Image 63 Contents
Page Mains Plug Warning Digitech Electronics RP21, RP21DDigitech III Table of Contents Introduction RP21D FeaturesSelect Program Apply PowerQuick Start Making ConnectionsFront Panel Guided Tour of the RP21DRear Panel Making Connections Getting StartedStereo Display Powering the RP21DProgram Mode About the RP21DEffects FootswitchesPrograms Expression PedalPreamp/Analog Modules Digital Effects ModulesEdge of the Earth Editing the Preamp Preamp DefaultsSelecting a Program Creating ProgramsThreshRatio AttackMedium CompressorCompressor HeavyCompressor LevelTube Distort Wah WahTube Distortion Wah Pedal Toe HeavyType Dirty Tube Gain Saving a Distortion DefaultType Fuzz Solid State DistortionDistort Low FuzzPunch Level PhaseBand Graphic Equalizer Tube GEQNoise Gate 80Hz 140Hz 250Hz 450HzTube GEQ Custom ThreshAtten AttackRelse Noise Gate LoThreshTypeSilencer2 Post T&DMaster Preamp Settings Noise Gate CustomDISTPan Mix DistByp Lvl DSPLvl Mstr TubeOn Lvl DSPLvl MstrNameUser Storing a User Preamp DefaultNaming a Default PreAmp CustomDefault List RP21D User’s Guide Section Two Editing Functions Digital Effects ConfigurationFX Dual Cho Changing EffectsFXThru Module CenterSpeed Depth WvFrm FXLvl DryLvl BalanceOutA PanA OutB PanB DlyA DlyB BalanceEffect Types Choruses and FlangersChorus Chorus Parameters Flanger Parameters FlangerPedal Phaser Parameters PhasersPhaser Parameters Pedal PhaserRotary Speaker Simulator Parameters Rotary Speaker SimulatorTremolo and Auto-Panner FeedbackTremolo & Auto Panner Parameters DelaysTremolo Auto PannerDelay Parameters FX Lvl Dry Lvl Balance Dly Time FdBck TapIt SmearFrequency Gain Dly a B Dly C D Out Multi-Effect Module Parameters Multi Effects Modules Chorus/Delay and Flange/DelayReverse Delay Time WarpSampler Reverbs Type ReverbGated Reverb Reverb ParametersOver Freq DispersionDiffusion Over TypeIncreasing, Shelf, and Reverse Shelf Delay CDelay D DetunersDtn E -H Pitch Shifters and HarmonyDtn a B Dtn C DPitch Shifters Parameters Whammy Effects Auto WahWhammy Effect Parameters Here are a couple of simple examples Auto Wah Effect ParametersEqualizers Graphic EqualizersParametric Equalizer Parameters Parametric EqualizersCabEmType Pre Digital Master MixCabinet Emulator Master Mix Dry WetStoring/Copying Programs NameStyx And StonesStore Prg toStyx And Sto Assigning On/Off Functions Select Contrl F.SwitchFoot Controller Functions Assigning ProgramsExpression Pedal Assignments Re-assign F.switch ?Assigning the Morph or Volume Assigning the WahSeries Midi Continuous Controllers ModifiersDynamic Filters Low Frequency OscillatorsFXLvl CC # Min Max Viewing, Changing, or Deleting AssignmentsTuner OutputMono Output Mode Cabinet Emulation Midi ChannelsPrg Rcv MapMIDI= User Program Receive MapProgram Transmit Map Midi RcvChnl TransChnlSysEx Channel and Midi Merge SysEx DumpSysEx Channel Midi Merge SysExDump UserPrg³PrgNum User Default DumpProgram Dumps SysExDump Bulk SystemPdlsBanks FS=Prg CCTran Assigning a Midi CC to PedalsAssigning a Midi CC to the Expression Pedal UsrDfltPreamp UserBank Names Volume Pedal UpdateFactory Reset Factory Reset?Push pdl forward,press Recalibrating the Expression PedalAre you sure ? Recalibrate Pedal ?RP21D Factory Program List Section Five AppendixInput Section SpecificationsRecognized Remarks