Honeywell WT6500 DC Power Wiring, Turbine Wiring and Distances, Turbine Current Rating and Wiring

Page 26

19

Turbine Installation

 

 

 

 

DC Power Wiring

TURBINE POLES

TURBINE TO CONTROLLER WIRE SIZE CHART

TURBINE WIRE

MAX DISTANCE (FT)

EMT CONDUIT (INCH)

#10 (#6 GND)

150

3/4

#8 (#4 GND)

200

1

#4 GND

EARTH

GROUND

STAKE

TURBINE JUNCTION BOX

SEE TURBINE TO CONTROLLER SIZE CHART ON SHEET 1

(2) #10 THWN-2 + #6 GND

¾” CONDUIT

MAX DISTANCE 3 FEET.

Figure 2.10 Power Wiring Diagram

Turbine Wiring and Distances

The HONEYWELL™ Wind Turbine and SMARTBOX™ Controller can be installed at a maximum distance of 200 feet apart. The SMARTBOX™ Controller and battery enclosure can be installed at a maximum distance of 10 feet apart.

Turbine Current Rating and Wiring

The turbine input is rated for 20 amps maximum Isc (short circuit). The recommended wire type is #10 AWG USE-2/RHW-2 or THWN-2, 90 degrees C wire for a turbine-to- Smart-Box distance of up to 150 feet. The wire gauge should be increased to #8 AWG for a distance of 150-200 feet. Due to the outside location of the turbine, a 70 degree C ambient temperature correction is recommended.

HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev 10

Image 26
Contents Honeywell Wind Turbine Thank You III Important Safety Instructions Safety InformationSafety Icons Page Table of Contents Specifications Introduction Shipping Contents Product DescriptionBefore Installing the Honeywell Wind Turbine Lift Point Wiring Turbine MountingIntroduction Personal Injury and Property Damage Hazard Site Selection Turbine with Electrical SystemsTurbine Installation Mounting Options Roofbox Mount Pole MountQuadpod Mount Turbine Wiring Ballast MountTurbine Component Diagram Turbine ComponentsSmartbox Controller Smartbox ControllerBattery Box Recommended Battery TypeJunction Box Junction Box EnclosureJunction Box Block Diagram Wind GeneratorTurbine Wiring Overview SMARTBOXControllerTurbine Current Rating and Wiring DC Power WiringTurbine Wiring and Distances Turbine Over-Current Protection Shock or Fire HazardControl Wiring Turbine Smartbox Controller Junction BOXGrounding Shock HazardTo Disable Wind Turbine Disconnect AC Power OperationTurbine Installation Specifications Technical Specifications Warranty Information Year Limited Warranty Limited WarrantyLimitations and Exclusions on Limited Warranty Legal Remedies Appendix Turbine Installation Drawings Pole Mount Roofbox Mounting Roofbox with Quadpod Mounting Ballast Mounting Symbols List Electrical One-Line Drawing PartSheet Notes Appendix WindTronics