ClearOne comm AP800 operation manual Unpacking, Controls and Connections, Front panel

Page 8

4

Introduction ~ Unpacking

Unpacking

ClearOne is not responsible ! for product damage incurred during shipment.

You must make claims directly with the carrier. Inspect your shipment carefully for obvious signs of damage. If the shipment appears to be damaged, retain the original boxes and packing material for inspection by the carrier. Contact your carrier immediately.

Ensure that the equipment shown below was received with your shipment.

Optional

www.gentner.com

Audio Products

AP800 Audio Conferencing System

Installation & Operation Manual

AP800 Installation

and Operation Manual

Figure 1.1. Equipment

Controls and Connections

AB

Figure 1.2. Front panel controls

The front panel buttons are also used to enter the front panel passcode. See

Lock Panel (page 15) for more details. The front panel passcode can also be established in AP-Ware. Refer to the AP-Ware help file for more information.

C D E F

Front panel

A.LCD. The two-line, 16-character-per-line LCD display is used for AP800 setup and level adjustments in conjunction with the four associated front- panel buttons.

B.Enter/▲▼ /ESC. These buttons are used to navigate the AP800’s menu system.

C.LED Meter. The LED bar meter is displays the audio level of any selected input or output on the AP800, as well as display echo return loss (ERL) and echo return loss enhancement (ERLE) for mic channels 1–8.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 8
Contents AP800 Audio Conferencing System AP800 Installation ClearOne Part No July 2002 Rev Table of Contents AP-Ware Software AppendicesIntroduction Product OverviewFeatures Professional Services Group Sales and Customer ServiceTechnical Support ClearOne Communications EuMEA GmbHFront panel UnpackingControls and Connections Rear panel Introduction ~ Controls and ConnectionsLink network will allow interconnection of up to eight Link NetworkLink bus Power requirements Equipment placementEquipment Requirements Auxiliary equipmentTo connect the AP800 Hardware SetupConnecting the unit Link connections Installation ~ InstallationNetworking Units To set the device ID Device IDsTo create a G-Link network Mixer Mode Installation ~ Installation Device typesEC reference To set mixer modeErrors Installation ~ LCD Programming Switching from one main menu category to anotherLCD Programming Menu TreesAdjusting a value Installation ~ LCD ProgrammingSelect Preset System parametersLock Panel Set PasscodePA Adaptive Mode Device IDUnit ID Gate ParametersLast Mic Mode Maximum Number of MicsFirst Mic Priority Gate RatioHold Time Decay RateRS-232 Manual AmbientTo determine ambient level Baud RateModem Mode Clear PasswordSerial Overrun Errors TimeoutInput Parameters Inputs 1-8, Input GlobalHigh Pass Filter Three-Band EQChairman Mic Adaptive AmbientEcho Canceller NLP AdjustInputs A, B, C, D AEC ReferenceOutput Parameters Routing ParametersOutputs 1-8, A-D Subbus 1Internal Subbus Echo Cancellation SetupRouting Guidelines Slave Unit EC Reference busMaster Unit Inputs, Outputs, ERL, and Erle Default MeterMeter Parameters Technical Services Group ~ 1-800-283-5936 USA ~ 64MB RAM DescriptionAP-Ware software requirements Installing AP-Ware To install AP-WareRemote Control Volume ControlTo increase volume To decrease volumeTo mute an output MutingTo mute an input Appendix a Specifications FCC, CSA, CEAppendix B Warranty This warranty is void ifAppendices ~ Appendix C Compliance Appendix C ComplianceFCC Part 15 compliance Control/Status a pinout Appendix D Connector PinoutsPin Number Definable Status Default Description Pin Number User Definable* Status Default Description Control/Status B pinout+5VDC Control/Status Pinout NoteAppendix E Accessories Appendices ~ Appendix E AccessoriesRS-232 COM DCE Port Pinout Pin Number ControlAppendix F Serial Commands Command syntaxAppendices ~ Appendix F Serial Commands MrefCommand Function AP800 Serial Commands40Appendices ~ Appendix F Serial Commands Error Codes Aamb AGCAmblvl ExplanationBaud DecayChairo DfltmERL ErleFPP FlowFMP Gain GateExamples ExampleGmode GratioHold LFPMaster LMOLVL Mdmode MEQDevice Mdmode Device MEQ CH BandMHP MinitMline MmaxMpass MtrxMref InputOutputmix Mtrx 18Mute NLPDevice Mute CH W Device NLP CHNOM OffaDevice NOM CH Device PAAPcmd ExampleEvent List LFP, PRESET, MUTE, GAIN, AGC, EQ, GMODE, Chairo PevntDevice Pevnt Location Event EventTout PresetRefsel UID VERDevice UID Device VERRouting Matrix Setup ~ Appendix G SWorksheetsInputs = Gated AppendicesSystemwide Parameters Auto Mix Parameters Appendices ~ Appendix G WorksheetsBus Glossary Glossary ~ A-DGlossary ~ E-S Glossary ~ T-Z Index Index ~ A-Z

AP800 specifications

ClearOne has established itself as a leader in the audio and video communication technology space, and the ClearOne COMM AP800 is a prime example of the company's commitment to providing high-quality communication solutions. The AP800 is an advanced audio processing unit specifically designed for professional audio environments, including conference rooms, auditoriums, and other large venues that require exceptional audio clarity and performance.

One of the standout features of the ClearOne COMM AP800 is its robust digital signal processing capabilities. It is equipped with powerful, sophisticated algorithms that enhance audio quality by minimizing background noise and echo, ensuring crystal-clear communication even in challenging acoustic environments. This makes the AP800 ideal for videoconferencing, teleconferencing, and live events where audio fidelity is paramount.

The AP800 features multiple microphone inputs, allowing users to connect a variety of microphone types, including boundary microphones and handheld units. This versatility enables configuration for different setups, ensuring that audio coverage is optimal for all participants regardless of their location within the space.

Another impressive characteristic of the ClearOne COMM AP800 is its user-friendly interface. The unit comes with a graphical interface that simplifies configuration and control. Users can easily manage audio settings, adjust levels, and monitor system performance in real time. This intuitive design streamlines setup and operation, making it accessible for users at all technical skill levels.

The AP800 also supports VoIP and SIP technologies, making it an ideal solution for businesses looking to integrate their audio systems with modern communication networks. This feature enhances interoperability with various communication platforms and devices, ensuring seamless connectivity for users.

For added flexibility, the ClearOne COMM AP800 can be integrated into larger audio systems. It can work harmoniously with other ClearOne products and third-party equipment, leveraging its modular design to create a comprehensive communication environment tailored to specific needs.

In summary, the ClearOne COMM AP800 represents a significant advancement in audio processing technology, offering state-of-the-art features for high-performance audio applications. Its powerful DSP capabilities, versatile microphone support, user-friendly interface, and seamless integration capabilities make it a must-have for any organization seeking to elevate their audio communication experience. With the AP800, ClearOne continues to push the boundaries of what's possible in professional audio technology.