Vanguard VI33PRA, VI33NRA manual Fireplace Insert Installation Into FRAMED-IN Enclosure

Page 10

10

INSTALLATION

Fireplace Insert Installation Into Framed-In Enclosure Installing Gas Piping To Fireplace Location

INSTALLATION

Continued

FIREPLACE INSERT INSTALLATION INTO FRAMED-IN ENCLOSURE

Installation of this fireplace insert involves installing fireplace insert into a framed-in enclosure. If using a mantel above the fireplace, you must follow the clearances shown in Figure 14, page 9. Follow these instructions to install the fireplace insert in this manner.

 

Insert

 

 

Framing

 

 

 

 

 

 

 

 

 

Height

25

9/

16

"

 

26

1/ "

 

 

 

 

 

 

4

Front Width

34 5/16"

 

35"

Depth

16

11/

16

"

17

1/ "

 

 

 

 

 

 

4

1.Frame in rough opening. Use dimensions shown in Figure 15 for the rough opening.

2.Install and properly ground GA3555, three-prong 120 volt elec- trical outlet, in fireplace insert. Follow instructions included in kit (see Accessories, page 30).

3.Install gas piping into fireplace location. This installation in- cludes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location.

4.Carefully set fireplace insert in front of rough opening with back of insert inside wall opening.

5.Carefully set fireplace insert into rough opening.

6.Attach flexible gas line to gas supply. See Connecting Fire- place Insert to Gas Supply, page 11.

7.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 16).

8.Check all gas connections for leaks. See Checking Gas Con- nections, page 12.

9.Install surround kit. See Installing Surround Kit (GS38 or GS43), pages 7 and 8.

Mantel Clearances for Insert Installation

If there is a mantel above masonry fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirements of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the mini- mum clearances shown, you must do one of the following:

raise the mantel to an acceptable height

remove the mantel

INSTALLING GAS PIPING TO FIREPLACE LOCATION

WARNING: A qualified service person must con- nect fireplace Insert to gas supply. Follow all local codes.

CAUTION: For propane/LP gas, never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and pro- pane/LP supply.

Installation Items Needed

Before installing fireplace insert, make sure you have the items listed below.

17 1/4"

26 1/4"

35"

Figure 15 - Rough Opening for Installing in Wall

Nails or

Wood

Screws

Nailing Flanges

Figure 16 - Attaching Fireplace Insert to Wall Studs

external regulator (supplied by installer) (propane/LP units only)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by lo- cal codes) (not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 30.

For..com

110150-01B

Image 10
Contents VI33NRA VI33PRA OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS Fireplace Insert Remote Ready GAS Fireplace InsertTable of Contents Safety InformationLog Base Assembly Product IdentificationLocal Codes Remote Control AccessoriesProduct Features UnpackingUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Blower Accessory InstallationInstalling Surround KIT GS38 or GS43 Check GAS TypeInstalling Hood Attaching LeftInstallation Clearances Fireplace Insert Installation Into Masonry FireplaceMantel Clearances for Insert Installation Fireplace Insert Installation Into FRAMED-IN EnclosureInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace Insert to GAS Supply Propane/LPPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Logs Pressure Testing Fireplace Insert Gas ConnectionsInstalling Remote Receiver Unit GhrctaInstalling 9-Volt Battery Not Included in Receiver Installing 9-VOLT BatteriesFor Your Safety Read Before Lighting Operating Fireplace InsertShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burners Only pilot stays litGhrc Series Operation Optional Remote OperationThermostat Control Operation Ghrcta Series OperationInspecting Burners Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible CauseMaintenance, Observed Problem Possible Cause Remedy Replacement Parts Wiring DiagramsSpecifications Service HintsIllustrated Parts Breakdown Remote Ready Model VI33NRAParts List KEY Part Number Description QTYRemote Ready Model VI33PRA 103877-01 Lighting Instruction Plate 100563-01 Fireplace Insert VI33NRA VI33PRA 101784-01 Magnet Catch 102307-01 Strike Plate WALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT Thermostat Switch Cleaning KIT CCKOwners Registration Form Tape 110150-01B Warranty Information