Vanguard VI33NRA Operating Fireplace Insert, Installing 9-VOLT Batteries, Lighting Instructions

Page 15

INSTALLATION

Installing 9-Volt Batteries

OPERATING FIREPLACE INSERT

For Your Safety Read Before Lighting Lighting Instructions

15

INSTALLATION

Continued

INSTALLING 9-VOLT BATTERIES

Two 9-volt batteries (not included) are required to operate this heater with the wireless hand-held remote control set. Install one battery in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery (Not Included) in Receiver

1.Locate back of receiver under front burner of heater.

2.Locate the battery clip mounted on the back of the receiver.

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

Remote

Terminal

Receiver

Wires

 

Battery Clip

9-Volt Battery

Figure 30 - Installing Battery in Remote Receiver

Installing 9-Volt Battery (Not Included) in Hand- Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery. Place battery into the bat- tery housing.

3.Replace battery cover onto remote control unit.

 

Model

Battery

 

Terminal

GHRC

 

Cover

Remote

 

Wires

 

 

Control Unit

 

 

 

Model

 

 

 

GHRCTA

9-VoltBattery

BatteryHousing

Figure 31 - Installing Battery in Hand-Held Remote Control Unit

OPERATING FIREPLACE INSERT

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING: You must operate this heater with the fireplace insert screen in place. Make sure fireplace insert screen is installed before running fireplace insert.

NOTICE: During initial operation of new fireplace insert, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

3.Set switch to OFF position.

WARNING: Burners will come on automatically within one minute when the remote selector switch is in the ON position after the pilot is lit.

For morevisit www..com

110150-01B

Image 15
Contents Remote Ready GAS Fireplace Insert OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS Fireplace Insert VI33NRA VI33PRASafety Information Table of ContentsProduct Identification Log Base AssemblyUnpacking Remote Control AccessoriesProduct Features Local CodesConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstalling Surround KIT GS38 or GS43 Blower AccessoryAttaching Left Installing HoodFireplace Insert Installation Into Masonry Fireplace Installation ClearancesInstallation Items Needed Fireplace Insert Installation Into FRAMED-IN EnclosureInstalling GAS Piping to Fireplace Location Mantel Clearances for Insert InstallationPropane/LP Connecting Fireplace Insert to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Insert Gas Connections Installing LogsGhrcta Installing Remote Receiver UnitOperating Fireplace Insert Installing 9-VOLT BatteriesFor Your Safety Read Before Lighting Installing 9-Volt Battery Not Included in ReceiverShutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterGhrcta Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationInspecting Burners Cleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause TroubleshootingMaintenance, Observed Problem Possible Cause Remedy Service Hints Wiring DiagramsSpecifications Replacement PartsRemote Ready Model VI33NRA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListRemote Ready Model VI33PRA 103877-01 Lighting Instruction Plate 100563-01 Fireplace Insert VI33NRA VI33PRA 101784-01 Magnet Catch 102307-01 Strike Plate Cleaning KIT CCK Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT Thermostat Switch WALL-MOUNT ON/OFF Switch GWMS2Owners Registration Form Tape 110150-01B Warranty Information