INSTALLATION

Installation Clearances Fireplace Insert Installation Into Masonry Fireplace

9

INSTALLATION

Continued

INSTALLATION CLEARANCES

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceil- ing, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 12.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 12).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

Example

*

2.Install and properly ground GA3555, three-prong 120 volt elec- trical outlet, in fireplace insert. Follow instructions included in kit (see Accessories, page 30).

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equip- ment shutoff valve. The flexible gas line must be the last item in- stalled on the gas piping. See Installing Gas Piping to Fireplace Location, page 10.

4.Carefully set fireplace insert in front of masonry fireplace with back of insert inside wall opening.

5.Attach flexible gas line to gas supply. See Connecting Fire- place Insert to Gas Supply, page 11.

6.Plug electrical cord into electrical outlet installed in step 2.

7.Carefully place fireplace insert into masonry fireplace.

8.Check all gas connections for leaks. See Checking Gas Con- nections, page 12.

9.Install brass trim after final finishing and/or painting of wall (see Figure 10, page 8).

17 1/4"

26 1/4"

35"

Figure 13 - Rough Opening for Installing in Masonry Fireplace

*Minimum 16 inches from Side Wall

Figure 12 - Minimum Clearance for Combustible to Wall

FIREPLACE INSERT INSTALLATION INTO MASONRY FIREPLACE

Installation of this fireplace insert involves installing fireplace insert into an existing masonry fireplace. If using a mantel above the fireplace, you must follow the clearances shown in Figure 14. Follow the instructions below to install the fireplace insert in this manner.

Minimum

Fireplace

Wall board or facing material (above fireplace) may be of combustible material, including decorative mantel ornaments or other similar projec- tions off of the facing material.

Fireplace

Fireplace Insert

Mantel Shelf

8"

6"

2 1/2"

Noncombustible Material May Project Off this Surface above the Insert Hood

13" 16" 19" 21"

 

Insert

Opening

Height

25 9/16"

26 1/4"

Front Width

34 5/16"

35"

Depth

16 11/16"

17 1/4"

1.Use dimensions shown in Figure 13 for the masonry fireplace opening.

Wire-mesh

 

 

Note: All vertical

 

 

measurements are

Screen

 

Supplied Hood Must

from top of insert hood

 

 

Be Used at All Times

opening to bottom

 

 

 

of mantel shelf.

 

 

 

 

 

 

 

 

 

 

Figure 14 - Minimum Mantel Clearances for Fireplace Insert Installation

For morevisit www..com

110150-01B

Image 9
Contents Unvented VENT-FREE GAS Fireplace Insert OWNER’S Operation and Installation ManualVI33NRA VI33PRA Remote Ready GAS Fireplace InsertSafety Information Table of ContentsProduct Identification Log Base AssemblyProduct Features Remote Control AccessoriesLocal Codes UnpackingDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Surround KIT GS38 or GS43 InstallationBlower Accessory Check GAS TypeAttaching Left Installing HoodFireplace Insert Installation Into Masonry Fireplace Installation ClearancesInstalling GAS Piping to Fireplace Location Fireplace Insert Installation Into FRAMED-IN EnclosureMantel Clearances for Insert Installation Installation Items NeededPropane/LP Connecting Fireplace Insert to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Insert Gas Connections Installing LogsGhrcta Installing Remote Receiver UnitFor Your Safety Read Before Lighting Installing 9-VOLT BatteriesInstalling 9-Volt Battery Not Included in Receiver Operating Fireplace InsertTo Turn OFF GAS To Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burners Only pilot stays litThermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrcta Series OperationInspecting Burners Cleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause TroubleshootingMaintenance, Observed Problem Possible Cause Remedy Specifications Wiring DiagramsReplacement Parts Service HintsRemote Ready Model VI33NRA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListRemote Ready Model VI33PRA 103877-01 Lighting Instruction Plate 100563-01 Fireplace Insert VI33NRA VI33PRA 101784-01 Magnet Catch 102307-01 Strike Plate WALL-MOUNT Thermostat Switch Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT CCKOwners Registration Form Tape 110150-01B Warranty Information