Desa P324 Wall Switch Installation, Optional Wireless HAND-HELD Remote Control Installation

Page 10

10

INSTALLATION

Wall Switch Installation

Optional Wireless Hand-Held Remote Control Installation

INSTALLATION

WALL SWITCH INSTALLATION

The installation of a wall switch allows you to activate the gas control valve without the normal household electricity since the valve operates on millivolt current supplied by the heat generated by the thermopile. To install the wall switch:

1.Remove the front refractory access panel by lifting up and an- gling out of the firebox opening (see Figure 13).

2.Use wire and connectors provided. Attach red wire to terminal marked TH/TP on control valve. Attach white wire to blade connector on open end of safety circuit wiring (see Wiring Diagram, page 27).

IN

 

ON

LO

T

 

I

 

P

 

FF O

IN

OUT

To Safety Circuit

Route Millivolt

 

Wires (Supplied)

 

 

Wall Switch

 

Through Gas Line

 

 

 

Conduit Sleeve

 

 

To Thermopile

 

TH

 

 

TP

 

 

THTP

 

 

 

 

(Back View)

Note: If any of the original wire from the unit control must be replaced, use the same type or a higher rated wire (25 ft. maximum length).

WARNING: Do not wire remote wall switch to main power supply (Standard 120v household current).

4.Locate wall switch in a convenient location.

5.After wire connections are complete, replace refractory access panel.

Figure 12 - Removing Front Refractory Access Panel (P325B/VP325 Model Shown)

Note: If any of the original wire as supplied must be replaced, use 18 AWG TYPE CL2 (UL) 105 C (25 ft. length MAXIMUM) or equivalent.

Figure 13 - Wall Switch Wiring Diagram

OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL INSTALLATION

Note: If using optional wireless hand-held remote control, the wall switch is no longer operational.

Installing Receiver

1.Remove the front refractory access panel by lifting up and angling out of the firebox opening (see Figure 12) to expose controls.

2.Disconnect wall switch wires from TH/TP terminals on con- trol valve and the blade connector on safety circuit wiring (see Figure 13 and Wiring Diagram on page 27).

3.Install remote receiver unit onto mounting bracket using the two plastic mounting clips (see Figure 14).

Receiver

Plastic

Mounting

 

Clips

 

Mounting

 

Bracket

Figure 14 - Installing Remote Receiver (Shown from Rear of Mounting Bracket)

For morevisit www..com

108660

Image 10
Contents Natural GAS For Your SafetyVent Decorative GAS Fireplace What to do if YOU Smell GASTable of Contents Safety InformationUnpacking Introduction Before YOU BeginProduct Specifications Selecting LocationClearances PRE-INSTALLATION PreparationMantel Clearances and Wall Details Corner Installation Guidelines FramingVenting Installation Typical B-Vent ConfigurationChecking for Proper Venting Min Roof PitchWall Switch Installation InstallationOptional Wireless HAND-HELD Remote Control Installation Installing 9-Volt Battery in Hand-Held Remote Control Unit GAS Line HOOK-UPEmber and PAN Material Placement OvertightenLOG Placement for P324/VP324 Models LOG Placement for P325B/VP325B ModelsCombustion AIR KIT Model AK4 Optional Appliance EnclosureInstalling Optional Glass Door Accessory Adjusting Glass DoorsLighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS to ApplianceOptional HAND-HELD Remote Operation Pilot AssemblyInspecting Burners Burner Flame PatternReplacement Parts Cleaning MaintenanceTechnical Service Service HintsTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Observed Problem Possible Cause Illustrated Parts Breakdown P324 and VP324 ModelsParts List KEY Part Number Description QTYBREAKDOWN44 P325B and VP325B Models LOG Assembly Accessories Wiring DiagramWarranty Information