Desa VP324, VP325(B) installation manual Ember and PAN Material Placement, Overtighten

Page 12

12

INSTALLATION

Gas Line Hook-Up (Cont.)

Ember and Pan Material Placement

INSTALLATION

Continued

DESA recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 19), and into the appliance, Once connected through the appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 20).

Before connecting the black iron gas line to the inside of the appliance a sediment trap must be included outside the appliance between the gas line and the gas shutoff valve. It must extend down three (3) inches beyond the center of the pipe. Prepare incoming black iron gas line with teflon tape or pipe joint compound (Check with local building codes).

CAUTION: Compounds used on threaded joints of gas piping shall be resistant to the action of Liquefied Petroleum (LP or propane), and should be applied lightly to ensure excess sealant does not enter the gas line.

WARNING: All gas piping and connections must be tested for leaks after the installation is completed.

After ensuring that the gas valve is on, apply a noncorrosive leak detection solution to all connec- tions and joints. If bubbles appear, leaks can be detected and corrected.

Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.

Complete your gas installation by connecting incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT

EMBER AND PAN MATERIAL PLACEMENT

1.Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 21).

2.Smooth the pan material just even with edges of the burner pan.

3.Remove the ember material from the bag and flatten small amounts into quarter size pieces and lay on top of the surface of the pan material (see Figure 22).

4.Place just enough to cover the entire surface and leave about a 1/2 inch gap under the lower grate members to allow air to flow (see Figure 23).

Grate

Vermiculite

Burner Pan

(Pan Material)

 

 

 

Figure 21 - Fill Entire Burner Pan with Vermiculite (P325/VP325 Models Shown)

 

Ember

Vermiculite

 

Grate

Material

Burner Pan

(Pan Material)

 

 

 

OVERTIGHTEN.

Sediment Trap

(Not Supplied)

3" Min.

(76mm)

Incoming 1/2" Gas Line Permitted by Local Codes

 

Wall

 

Appliance

Side

Of

 

Figure 22 - Ember Material on Surface of Pan Material (Vermiculite) (P325/VP325 Models Shown)

Pan and Ember

Figure 19 - Sediment Trap

 

 

Red Surface Indicates For

 

 

Propane/LP Use Only

Pilot Adj

 

 

Flexible Gas Line

 

Gas Shutoff

 

 

Do NOT Kink

 

 

Valve

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

T

 

 

 

 

O

 

 

 

 

L

 

 

 

 

I

 

 

 

 

P

 

 

 

 

OFF

 

 

Note:

IN OUT

 

1/2" NPT

1) Wire Connections

 

Outlet

 

Not Shown for Clarity

Inlet

Incoming

 

Pressure

2) * 1/8" NPT Plugged

Gas Line

Pressure

Tap

 

Tapping

 

 

Tap

 

 

 

 

 

Figure 20 - Connecting Flexible Gas Line to Millivolt Valve

Grate Material

0.5"

0.5"

Burner Pan

Figure 23 - Pan and Ember Material Clearances (P325/VP325 Models Shown)

For morevisit www..com

108660

Image 12
Contents For Your Safety Vent Decorative GAS FireplaceNatural GAS What to do if YOU Smell GASTable of Contents Safety InformationUnpacking Introduction Before YOU BeginProduct Specifications Selecting LocationPRE-INSTALLATION Preparation ClearancesMantel Clearances and Wall Details Corner Installation Guidelines FramingVenting Installation Typical B-Vent ConfigurationChecking for Proper Venting Min Roof PitchInstallation Wall Switch InstallationOptional Wireless HAND-HELD Remote Control Installation Installing 9-Volt Battery in Hand-Held Remote Control Unit GAS Line HOOK-UPEmber and PAN Material Placement OvertightenLOG Placement for P324/VP324 Models LOG Placement for P325B/VP325B ModelsCombustion AIR KIT Model AK4 Optional Appliance EnclosureInstalling Optional Glass Door Accessory Adjusting Glass DoorsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS to AppliancePilot Assembly Inspecting BurnersOptional HAND-HELD Remote Operation Burner Flame PatternCleaning Maintenance Technical ServiceReplacement Parts Service HintsTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Observed Problem Possible Cause Illustrated Parts Breakdown P324 and VP324 ModelsParts List KEY Part Number Description QTYBREAKDOWN44 P325B and VP325B Models LOG Assembly Accessories Wiring DiagramWarranty Information