Desa VP324, VP325(B) installation manual Troubleshooting

Page 20

20

TROUBLESHOOTING

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Pilot goes out when wall switch is ON

1. Millivolt output on thermopile too high

1. Replace thermopile

 

 

 

Spark ignitor will not light pilot after re- peated triggering of red button

1.Defective ignitor (no spark at electrode)

2.Defective pilot or misaligned electrode at pilot (spark at electrode)

3. No gas or low gas pressure

4.If using propane/LP gas, no propane/LP gas in tank

1.Check for spark at the electrode and pi- lot; if no spark and electrode wire is properly connected, replace ignitor

2.Using a match, light pilot. If pilot lights, turn off pilot and trigger the red button again. If pilot lights, an improper gas/air mixture caused the improper lighting and a longer purge period is recommended. If pilot will not light, check gap at electrode and pilot. Gap should be 1/8" to have a strong spark. If okay, replace pilot

3.A) Check remote shut off valves from fireplace. Usually there is a valve near the fireplace and sometimes there is a valve near the main. There can be more than one (1) valve be- tween the fireplace and main

B)Low pressure can be caused by a va- riety of situations such as bent line, too narrow diameter of pipe, or even low line pressure. Check for kinked lines. If none, consult with plumber or gas supplier

4.Check propane/LP supply and contact local propane/LP supplier

For morevisit www..com

108660

Image 20
Contents For Your Safety Vent Decorative GAS FireplaceNatural GAS What to do if YOU Smell GASTable of Contents Safety InformationUnpacking Introduction Before YOU BeginProduct Specifications Selecting LocationMantel Clearances and Wall Details PRE-INSTALLATION PreparationClearances Corner Installation Guidelines FramingVenting Installation Typical B-Vent ConfigurationChecking for Proper Venting Min Roof PitchOptional Wireless HAND-HELD Remote Control Installation InstallationWall Switch Installation Installing 9-Volt Battery in Hand-Held Remote Control Unit GAS Line HOOK-UPEmber and PAN Material Placement OvertightenLOG Placement for P324/VP324 Models LOG Placement for P325B/VP325B ModelsCombustion AIR KIT Model AK4 Optional Appliance EnclosureInstalling Optional Glass Door Accessory Adjusting Glass DoorsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS to AppliancePilot Assembly Inspecting BurnersOptional HAND-HELD Remote Operation Burner Flame PatternCleaning Maintenance Technical ServiceReplacement Parts Service HintsTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Observed Problem Possible Cause Illustrated Parts Breakdown P324 and VP324 ModelsParts List KEY Part Number Description QTYBREAKDOWN44 P325B and VP325B Models LOG Assembly Accessories Wiring DiagramWarranty Information