Desa P325(B), VP324 GAS Line HOOK-UP, Installing 9-Volt Battery in Hand-Held Remote Control Unit

Page 11

INSTALLATION

Optional Wireless Hand-Held Remote Control Installation (Cont.) Gas Line Hook-Up

11

INSTALLATION

Continued

4.Connect wires to control circuit. Connect white wire to termi- nal marked TH/TP on control valve. Connect red wire to male blade connector provided at open end of safety circuit wiring (see Wiring Diagram, page 27).

5.Locate the battery clip mounted on the back of the receiver (see Figure 15).

6.Slide 9-volt battery (not included) through the clip. Note: Only use alkaline battery.

7.Attach the terminal wires to the battery (see Figure 15).

8.Replace refractory brick access panel.

 

9-Volt Battery

Battery

Receiver

Clip

 

Terminal

 

Wires

 

Figure 15 - Installing Battery in Receiver

Installing 9-Volt Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery (not included). Place bat- tery into the battery housing. Note: Only use alkaline battery.

3.Replace battery cover onto remote control unit.

GAS LINE HOOK-UP

WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.

WARNING: Before you proceed, make sure your gas supply is OFF.

A manual shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 17.

In conformance with local codes, route a 1/2" NPT gas line towards the appliance coming in from any of the 3 directions shown in Figure 18.

CAUTION: Do not kink flexible gas line.

Typical Exterior Wall Gas

Shutoff

Shutoff Installation

Valve

Key

 

 

Extension

Figure 17 - Manual Shutoff Valve Installation

Battery

Remote

Cover

Control Unit

Terminal Wires

9-Volt Battery

Battery

Housing

Figure 16 - Installing Battery in Hand-Held Remote Control Unit

1/2" NPT Incoming

Black Iron Gas Line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

3/8"

 

 

 

 

 

 

 

 

7"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7"

Alternate Gas Supply Through Sub-Floor

Flexible Gas Line

(1 Provided) Can

Be Extended Out

Either Side

105/8"

Figure 18 - Routing Incoming Gas Line

For more information, visit www.desatech.com

108660

Image 11
Contents What to do if YOU Smell GAS For Your SafetyVent Decorative GAS Fireplace Natural GASSafety Information Table of ContentsUnpacking Before YOU Begin IntroductionSelecting Location Product SpecificationsMantel Clearances and Wall Details PRE-INSTALLATION PreparationClearances Framing Corner Installation GuidelinesTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingOptional Wireless HAND-HELD Remote Control Installation InstallationWall Switch Installation GAS Line HOOK-UP Installing 9-Volt Battery in Hand-Held Remote Control UnitOvertighten Ember and PAN Material PlacementLOG Placement for P325B/VP325B Models LOG Placement for P324/VP324 ModelsAppliance Enclosure Combustion AIR KIT Model AK4 OptionalAdjusting Glass Doors Installing Optional Glass Door AccessoryTo Turn OFF GAS to Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Pilot AssemblyInspecting Burners Optional HAND-HELD Remote OperationService Hints Cleaning MaintenanceTechnical Service Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Observed Problem Possible Cause P324 and VP324 Models Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListBREAKDOWN44 P325B and VP325B Models LOG Assembly Wiring Diagram AccessoriesWarranty Information