Foster 9606801 user manual Cooker hob nozzle replacement, Different types of gasses

Page 14

ENGLISH

INSTALLER INSTRUCTIONS

Gas

 

Burner

Rated

Rated con-

Injector

Min

 

 

 

capacity

sumption

 

rated capacity

type

Series

No.

Ref.

 

(KW)

(l/h)

(ø mm)

(KW)

 

 

 

 

 

 

 

 

 

 

 

2

Auxiliary

1,00

95

0,72

0,52

 

 

 

 

 

 

 

 

 

 

3

Semi-quick

1,75

167

0,97

0,52

 

II

4

Quick

2,70

257

1,08

0,90

 

 

5

Triple crown

3,50

333

1,35

1,80

GASMETHANE mbar20G20

 

10

Dual

4,50

429

i 0.72 / and 1.02

i 0.46 / and 0.66

 

 

 

 

 

 

 

 

 

6

Auxiliary

1,10

105

0,73

0,52

 

III

7

Semi-quick

1,75

167

0,98

0,52

 

8

Quick

3,00

285

1,26

0,90

 

 

 

 

 

 

 

 

 

 

 

 

9

Triple crown

3,80

362

1,35

1,80

 

 

11

Auxiliary

1,00

95

0,72

0,52

 

 

 

 

 

 

 

 

 

AE

12

Semi-quick

1,75

167

0,97

0,52

 

13

Quick

3,00

285

1,32

0,90

 

 

 

 

 

 

 

 

 

 

 

 

14

Dual gear

5,00

476

i 0.75 / and 1.58

i 0.30 / and 1.40

The appliance is tested for methane gas G20 (2H) at a pressure of 20 mbar. When using with other types of gas it is necessary to replace the burner nozzles, and adjust the minimum flame on the gas taps. For nozzle replacement, proceed as described in the following paragraphs.

11.1 Cooker hob nozzle replacement

IMPORTANT: Before completing the following operations, always make sure that the appliance is disconnected from the power mains.

1.Remove the grids, remove all flame spreading caps and crowns.

2.Using a 7 mm tube spanner, unscrew the burner nozzles [Fig.7].

3.Proceed with burner nozzle replacement based on the type of gas to be used (table “Adapting to

different types of gasses [Page 31]).

4. Correctly reposition the burner in its seat.

Fig. 7: nozzle replacement

32

Image 14
Contents Abstract Table of Contents Usage warnings Position of the identification plateSafety warnings Do not Allow Children to Come Close or Play with ITKnow your appliance Flush built-in cooker hobs flush-mount edgePositioning in the work top First installationFor further information on cleaning see Pressing it by hand Fig Cooker hob distancesMilling surface Fig Once these operations have been Accurately clean millingFastening the cooker hob to the cabinet Fixed hooks Sliding hooks Standard edge 8 mm Flush-mount edge Q4 only for S4000 seriesFixed brackets Standard edge 8 mmRoom ventilation Connection to liquid gasDischarging combustion products exhaust Adapting to different types of gassesCorrectly reposition the burner in its seat Cooker hob nozzle replacementDifferent types of gasses Instructions for urban and methane gas Adjustment of the minimumElectrical connection of the cooker hob Instructions for liquid gas LPGCooker hob use Lighting the burnersStandard burner knob Diameter paragraph Practical recommendations for burner usePot diameter Cleaning gas components Cleaning and maintenanceCleaning the stainless steel Daily ordinary cleaningKey Tipo di bordoFori da incasso Edge type4000 = 560mm = 480 mm N7253V = 830 mm = 480 mmN7251V N7254V = 1159 mm = 348 mm= 360 mm = 430 mmN7277V = 1162 mm = 351 mm QuadraN7215V N7211VN7223V = 309 mm = 454 mm N7238V= 480 mm N7610V = 770 mm N7615V = 560 mm = 840 mm = 480 mm= 770 mm N7053V-10 = 560 mm = 480 mm N7055V-10= 840 mm = 270 mm = 480 mmLisa N7290VN7075V N7047VFT1 N7048V = 770 mm = 480 mm FaustEleonora N7095V = 770 mm = 480 mm N7295VN7097V N7297V = 950 mm = 480 mm N7067V = 560 mm = 480 mm N7066VN7266V N7063V = 420 mm = 480 mm N7367VR145 N7024V N7044V = 740 mm = 480 mm Elettra Pandora= 560 mm = 480 mm N7065V N7017VA AlienN7021V = 740 mm = 480 mm N7023V N7042V = 560 mm N7038V Angolare15 F2000 = 560 mm = 480 mmN7260V AlfaN7052V 500 mm N7051VG N7260V = 840 mm = 480 mm