Gas Hook – Up
continued
5.When connecting regulator assembly to the valve, hand tighten the quick coupling nut clockwise to a complete stop. Do not use a wrench to tighten. Use of a wrench may damage the quick coupling nut and result in a hazardous condition.
6.Open the tank valve fully (counterclockwise). Apply the soap solution with a clean brush to all gas connections. See below. If growing bubbles appear in the solution the connections are not properly sealed. Check each fitting and tighten or repair as necessary.
üSpecified clearance maintained 24”(61cm) from combustibles.
üAll internal packaging removed.
üKnobs turn freely.
üBurners are tight and sitting properly on orifices.
üPressure regulator connected and set. Gas connections to grill using hose & regulator assembly provided
üUnit tested and free of leaks.
üUser informed of gas supply shut off valve location
USER, PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
7.If you have a gas connection leak you cannot repair, turn gas OFF at supply tank, disconnect fuel line from your grill and call
8.Also apply soapy solution to the tank seams. See below. If growing bubbles appear, shut tank OFF and do not use or move it! Contact an LP gas supplier or your fire department for assistance.
To disconnect L.P. gas cylinder:
1.Turn the burner valves off.
2.Turn the tank valve off fully (turn clockwise to stop).
3.Detach the regulator assembly from the tank valve by turning the quick coupling nut counterclockwise.
Installer Final Check List
PROPANE CYLINDER CAUTIONS
a)Do Not store a spare
b)NEVER fill the cylinder beyond 80 percent full.
c)If the information in “a” and “b” is not followed exactly, a fire or explosion causing death or serious injury may occur.
14