Olfa 720-0430 manual GAS Hook UP

Page 14

Section Three

GAS HOOK UP

NEVER CONNECT AN UNREGULATED GAS SUPPLY LINE TO THE APPLIANCE. USE THE REGULATOR/HOSE ASSEMBLY SUPPLIED.

This is a liquid propane configured grill. Do not attempt to use a natural gas supply unless the grill has been reconfigured for natural gas use.

Total gas consumption (per hour) of this stainless steel gas grill with all burners on “IGNITE/HI”:

Main burner

50,000

Btu/hr.

Rotisserie burner 10,000

Btu/hr

Side burner

12,000

Btu/hr

 

Total

72,000

Btu/hr.

L.P. TANK REQUIREMENT

A dented or rusty L.P. tank may be hazardous and should be checked by your L.P. supplier. Never use a cylinder with a damaged valve. The L.P. gas cylinder must be constructed and marked in accordance with the specifications for L.P. gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable. Overfilling prevention device (OPD) shall be provided on cylinder & QCCI connection on the cylinder valve, ANSI/CGA-V-1. The cylinder supply system must be arranged for vapor withdrawal. The cylinder must include a collar to protect the cylinder valve. The cylinder must be provided with a shut off valve terminating in an L.P. gas supply cylinder valve outlet specified, as applicable, for connection type

QCC1 in the standard for compressed gas cylinder valve outlet and inlet connection ANSI/CGA-V-1.

Manifold pressure: 10”(25.4cm) water column (W.C.).

L.P. GAS HOOK-UP

Ensure that the rubber “O” Ring on the LP cylinder valve are in place and that the hose does not come into contact with the grease tray or the grill head.

CONNECTION

Your stainless steel grill is equipped with gas supply orifices for use only with liquid propane gas. It is also equipped with a high capacity hose/regulator assembly for connection to a standard 20lb. L.P. cylinder (18-1/4” (46.35cm) high, 12-1/4”(31cm) diameter). To connect the L.P. gas supply cylinder, please follow the steps below:

1.Make sure tank valve is in its full off position (turn clockwise to stop)

2.Check tank valve to assure it has proper external male threads (type 1 connection per ANSIZ21.81)

3.Make sure all burner valves are in their off position.

4.Inspect valve connections, port, and regulator assembly. Look for any damage or debris. Remove any debris. Inspect hose for damage. Never attempt to use damaged or obstructed equipment. See your local L.P. gas dealer for repair.

13

Image 14
Contents USE and Care Guide Table of Contents Precautions Proper Placement and Clearance GrillSafety Practices to Avoid Personal Injury Do not Leave the Grill Unattended While CookingPrecautions Side Buener Control Panel Assembly Side Shelf Wooden Mount Panel Assembly Side Shelf Push BAR Assembly Rear Burner Igniter Wire Assembly Side Burner LID BrACKET Assembly Rotisserie KIT Assembly Propane Tank Assembly GAS Hook UP Installer Final Check List GAS HOOK-UPGeneral Leak TestingBefore Testing To TestOperating Instructions Grill Lighting InstructionsTo Light the Grill Burner To Match Light the Grill Flame Characteristics Lighting Illustrations Care and Maintenance Stainless SteelHOW to Replace Main Burner Burner GrateBefore Calling for Service Trouble ShootingSpider and Insect WARNING!!! When to Look for Spiders Problems What to doExploded View Parts List REF# Description QTY100 Ordering Parts Grill HintsGrill Cooking Chart MeatsPoultry Tenderloin Porterhouse Bone, Sirloin Fish Seafood Grill Recipe Suggestions Beef and Lamb Kabobs Vegetable KabobsFajitas Eggplant CaviarPork Roast Chicken Tandoori StyleSpare Ribs TurkeyLimited Warranty Stainless Steel OUT Door GAS Grill