Cylinder Connection: Ensure the gas regulator hose is kink free. Remove the cap or plug from the cylinder fuel valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand tighten clockwise. Do not use tools. Leak test all joints prior to using the grill. A leak test must be performed annually and each time a cylinder is hooked up or if a part of the gas system is replaced.

If this grill is to be connected directly to a house propane gas supply line, follow the instructions for the natural gas hook-up. Optional side burners must also follow the natural gas hook-up instructions.

Note: The propane tank heat shield is not required when the grill is connected to a fixed fuel supply, as its sole function is to shield the propane tank normally used with the grill. Ensure that the supply pressure is 11 inches water column.

Natural Gas Hook-Up: These connections must be made by a licensed gas fitter. This natural gas grill is supplied with a gas supply hose (complete with a quick disconnect) designed for natural gas and certified for outdoor use. The gas grill is designed to operate at an inlet pressure of 7 inches water column. Piping and valves upstream of the quick disconnect are not supplied. The installation must comply with CAN B149.1 Natural Gas and Propane installation code in Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be sufficiently sized to supply the BTU/h specified on the rating plate, based on the length of the piping run.

The quick disconnect must not be installed in an upward direction and a readily accessible manual shut-off valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The flared end of the hose must be connected to the fitting on the end of the manifold tube or flex tube (if applicable) as illustrated in the Natural Gas Hose Attachment diagram. Tighten using two wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints prior to using the gas grill.

WARNING!

The installation must be performed by a licensed gas fitter, and all connections must be leak tested before operating the grill.

Do not route hose underneath the drip pan.

Do not route hose between bottom shelf space and back panel.

Do not route hose over top of rear panel.

Ensure all hose connections are tightened using two wrenches. Do not use Teflon tape or pipe dope on any hose connection.

Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a fire.

Leak test all the connections using a soap and water solution as per the leak testing instructions found in the manual.

The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 0.5 psi (3.5 kPa).

The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at

test pressures equal to or less than 1/2 psi (3.5 kPa).

www.napoleongrills.com

Image 6
Contents Prestige Conditions And Limitations Safe Operating Practices Dimensions Propane Cylinder Specifications General InformationGas Hook-Up Instructions Page Leak Testing Instructions Lighting Instructions Cooking Instructions Infrared Heat Infrared Grilling Chart Food Control Setting Cooking Time Helpful SuggestionsCleaning Instructions Maintenance Instructions Replacement Screen N565-0002 Troubleshooting Problem Possible Causes SolutionClean or replace as required Ordering Replacement Parts Warranty InformationRecord information here for easy reference Page Avertissement Garantie À VIE Limitée DU Président Conditions Et LimitationsPratiques Sécuritaires D’utilisation Dimensions Information Générale Instructions De Branchement Du GazSpécifications Pour La Bonbonne De Propane Avertissement Test De Détection De Fuites Instruction D’allumage FermezInstructions D’opération Chaleur Infrarouge Tableau de cuisson à l’infrarouge Nettoyage Page Instructions D’entretien Pour ajuster le volet d’airÉcrans de rechange N565-0002 Problème Causes possibles Solutions Guide De DépannageNettoyez le tube du venturi Commande De Pièces De Rechange Information Sur La GarantieInscrivez l’information ici pour y avoir accès facilement Getting Started Pour CommencerN570-0086 #14 x 1/2 810mm Propane Only Propane Seulement Propane Only N570-0086 #14 x 1/2 810mm Propane Only Propane Seulement Disposable grease tray jetable du récipient à graisse N570-0086 #14 x 1/2 N430-0002 810mm TOP Bottom N105-0011 door bushing N160-0022 pivot pin clip 500RB 500RSIB N715-0093 N520-0034 N305-0083 Rotisserie Kit Assembly Instruction Instructions D’assemblage De L’ensemble De RôtissoireN160-0002 Page Propane Natural Propane GAZ Naturel P500/P500RB Parts List / Liste Des Pièces Description RB UnitsP500/P500RB Parts List / Liste Des Pièces P500/P500RB Parts List / Liste Des Pièces P500/P500RB Parts Diagram / Diagramme DE Pièces P500RSIB Parts List / Liste Des Pièces Description RsibDescription N020-0142 P500RSIB Parts Diagram / Diagramme DE Pièces Accessories & Parts Order Form BON DE Commande Pour PIÈCES/ACCESSOIRES Page Page N415-0247