Desa (V)TC36N SERIES Replacement Parts, Service Hints, Technical Service, Specifications

Page 31

REPLACEMENT PARTS SPECIFICATIONS SERVICE HINTS TECHNICAL SERVICE

31

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESAʼs Customer Service Depart- ment at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA at 1-866-672-6040 for referral information.

When calling DESA, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation or troubleshooting. If so, contact DESAʼs Customer Service Depart- ment at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESAʼs technical service web site at www.desatech.com.

SPECIFICATIONS

Btu

18,000/26,000 Btu/hr

17,000/24,000 Btu/hr

Gas Type

Natural

Propane/LP

Ignition

Piezo

Piezo

Manifold Pressure

3.5" w.c.

10.0" w.c.

Minimum Inlet

5.5" w.c.

11.0" w.c.

Supply Pressure

 

 

Dimension (H x W x D) Fireplace

 

 

(Actual size of firebox.

36" x 41" x 21 1/8"

36" x 41" x 21 1/8"

Measurements do not include

914 x 1041 x 537 mm

914 x 1041 x 537 mm

nailing flanges or standoffs).

 

 

Carton

38" x 44" x 22"

38" x 44" x 22"

 

965 x 1118 x 559 mm

965 x 1118 x 559 mm

Weight, lbs/kg*

 

 

Fireplace

165 lbs/75 kg

165 lbs/75 kg

Shipping

168 lbs/76 kg

168 lbs/76 kg

 

 

 

116192-01B

www.desatech.com

Image 31
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySave this manual for future reference Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Vertical Horizontal H Horizontal Termination ConfigurationsCorner Installation Vertical Horizontal H 1 + Min Max 12 max 18 max 20 max Venting with Two 90 ElbowsVertical Horizontal H Horizontal H 1 + Min Max 12 max 18 max 20 maxFlat Ceiling Installation Installation for Vertical TerminationConnect a section of pipe and extend up through the hole Vertical Horizontal H Min Max 20 max Vertical Termination ConfigurationsVertical Horizontal H 1 + Min Max 20 max Venting with One 90 ElbowVertical Venting High Altitude Installation= 40 max Check GAS Type Venting InstallationFireplace Installation Installing Optional Blower AccessoriesBlower see Figure Model BKT InstallationBy turning knob fully counterclockwise before continuing Decal on the firebox bottom approximately 12 in frontBlower see , Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyOr servicing. Correct all leaks at once Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Installing Remote ReceiverRemoving Louver Panels Cleaning Glass Door Installing Lava Rock and Glowing EmbersRemoving Glass Doors Lighting Instructions Installing Brick Liner Models BL36DASA and BL36DHASAFor Your Safety Read Before Lighting Operating FireplaceShutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Safety FeaturesManual Mode Auto Thermostatic ModeOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersTroubleshooting Thermopile leads disconnected or im Is low Remote controlInlet gas pressure is too low CompanyAbove Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceModels TC36N, VTC36N, TC36P and VTC36P Illustrated Parts BreakdownKEY Part Number TC36N/P VTC36N/P Description QTY Parts ListBurner Assembly for Models TC36N, VTC36N, TC36P and VTC36P KEY Part Number Description QTY Accessories Owners Registration Form Industrial Drive Box Bowling Green, KY 116192-01B Industrial Drive P.O. Box Model Serial No Date Purchased