Desa (V)TC36P SERIES, (V)TC36N SERIES installation manual Accessories

Page 36

36

ACCESSORIES

ACCESSORIES

NOTICE: All accessories may not be available for all fireplace models.

Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DESAʼs Sales Department at 1-866-672-6040. for information. You can also write to the address listed on the back page of this manual.

BRICK LINER

(Not Shown)

BL36DA - Textured Refractory Brick Liner Kit

BL36DSA - Standard Refractory Brick Liner Kit BL36DHA - Textured Refractory Herringbone Brick Liner Kit BL36DHSA - Standard Refractory Herringbone Brick Liner Kit

This brick liner adds a touch of style to your direct-vent fireplace. Complete installation instructions included in this manual.

FLEXIBLE GAS LINE CONNECTOR - GA5081

(Not Shown)

For all models.

MANUAL BLOWER KIT - BK

Manual variable control blower accessory provides better heat dis- tribution. Complete installation and operation instructions included in this manual.

THERMOSTATICALLY- CONTROLLED BLOWER KIT - BKT

Provides better heat distribution. Blower turns off and on automati- cally, as needed. Complete installation and operation instructions included in this manual.

PROPANE/NATURAL GAS CONVERSION KIT

(Not Shown)

PCDM-36TC- Propane/LP Gas Conversion Kit NCDM-36TC- Natural Gas Conversion Kit

FACE/LOUVER PANEL KIT (Not Shown)

FPD36 - Filigree Panel Kit - Black

FPD36B - Filigree Panel Kit - Brushed Brass

FPD36P - Filigree Panel Kit - Platinum

FPD36PB - Filigree Panel Kit - Polished Brass

LOUVER TRIM KIT (Rolled Louvers Only) (Not Shown)

LT36B - Rolled Louver Trim Kit - Brushed Brass

LT36P - Rolled Louver Trim Kit - Platinum

LT36PB - Rolled Louver Trim Kit - Polished Brass

DEFLECTION HOODS

(Not Shown)

HD36 - Hood - Black (2" Brow)

PERIMETER TRIM KIT

(Not Shown)

PT36 - Perimeter Trim Kit - Black

PT36B - Perimeter Trim Kit - Brushed Brass

PT36P - Perimeter Trim Kit - Platinum

PT36PB - Perimeter Trim Kit - Polished Brass

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCTB SERIES

Allows the fireplace to be operated in a manually or thermostati- cally-controlled mode. You can adjust your heat settings and turn the fireplace on or off without leaving the comfort of your easy chair.

RECEIVER AND HAND-HELD ON/OFF REMOTE CONTROL KIT - GHRCB SERIES

Allows the fireplace to be turned on and off conveniently.

WALL MOUNTED THERMOSTAT CONTROL KIT - GWMT1 (Not Shown)

Allows easy wall access for thermostatic operation of your fire- place.

WALL MOUNTED ON/OFF SWITCH - GWMS2 (Not Shown)

Allows burner system to be turned on and off with a wall switch.

www.desatech.com

116192-01B

Image 36
Contents For Your Safety For Your Safety What to do if YOU Smell GASSave this manual for future reference Table of Contents Safety InformationSafety Information Product Identification Local CodesProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Siding Standoff Combustible Horizontal Termination Configurations Vertical Horizontal HCorner Installation Venting with Two 90 Elbows Vertical Horizontal H Horizontal H 1 +Min Max 12 max 18 max 20 max Vertical Horizontal H 1 + Min Max 12 max 18 max 20 maxInstallation for Vertical Termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Vertical Termination Configurations Vertical Horizontal H 1 + Min Max 20 maxVenting with One 90 Elbow Vertical Horizontal H Min Max 20 maxHigh Altitude Installation Vertical Venting= 40 max Venting Installation Fireplace InstallationInstalling Optional Blower Accessories Check GAS TypeModel BKT Installation By turning knob fully counterclockwise before continuingDecal on the firebox bottom approximately 12 in front Blower see FigureInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Blower see ,Connecting Fireplace to GAS Supply Checking GAS ConnectionsOr servicing. Correct all leaks at once Installing Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver REMOVING/REPLACING Glass DoorRemoving Louver Panels Installing Lava Rock and Glowing Embers Cleaning Glass DoorRemoving Glass Doors Installing Brick Liner Models BL36DASA and BL36DHASA For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsManual Lighting Procedure To Turn OFF GASOptional HAND-HELD Remote Operation Shutting Off Burners Only pilot stays litSafety Features Manual ModeAuto Thermostatic Mode ON/OFF Series Model GhrcbOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Is low Remote control Inlet gas pressure is too lowCompany Thermopile leads disconnected or imGas leak. See Warning statement AboveReplacement Parts Service HintsTechnical Service SpecificationsIllustrated Parts Breakdown Models TC36N, VTC36N, TC36P and VTC36PParts List KEY Part Number TC36N/P VTC36N/P Description QTYBurner Assembly for Models TC36N, VTC36N, TC36P and VTC36P KEY Part Number Description QTY Accessories Owners Registration Form Industrial Drive Box Bowling Green, KY 116192-01B Model Serial No Date Purchased Industrial Drive P.O. Box