Desa (V)V36EN installation manual Model BKT Installation, Blower Wiring Diagram

Page 18

18

FIREPLACE INSTALLATION

Installing Optional Blower Accessory (Cont.)

FIREPLACE INSTALLATION

Continued

Model BKT Installation

Note: When installing the BKT thermostatically-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed.

1.Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower assembly. Insert the phillips screw into all three pieces and tighten securely (see Figure 28, page 18).

2.Connect wire harness and power cord terminals. Connect the blue jumper wire to the blower motor terminal and the right side terminal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal.

Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely.

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 28 in order to sense temperature and properly operate. The blower will be held in position against the back wall by the magnets incorpo- rated onto the blower housing (see Figure 28).

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and thermal switch, and that the screw for the thermodisc bracket and green ground wire is tight.

Power Cord

White Wire

Blue Wire Magnetic

Thermal

Strips

Switch

Air Flow

Bracket

Black

Direction

 

Wire

 

Phillips

 

Screw

 

Thermal Switch

Ring Terminal

on Green Wire

 

Air Flow Direction

 

Magnets

Route BKT

 

Blower Through

Thermodisc

This Area

 

Side View Firebox Bottom

Blower

Location

Figure 28 - Blower Model BKT

 

5.Mount the speed control box against the mounting plate pro- vided in the lower fireplace cavity by placing the plastic control shaft forward through the round hole (see Figure 26, page 17).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise un- til it is tight against mounting plate. Place control knob pro- vided on shaft (see Figure 26, page 17).

7.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Also double check all wire leads and make sure wire rout- ing is not pinched or in a precarious position. Correct accordingly.

8.Turn on power to duplex outlet if previously turned off per the warning in column 2, page 16.

9.Plug in blower power cord to duplex outlet.

10.The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be ad- justed by rotating the control knob. To turn off, turn knob fully counterclockwise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically.

11.Peel off the backing paper and stick the supplied wiring dia- gram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27, page 17).

.

Blower Wiring Diagram

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2

Black

 

On

 

Blue

110/115

V.A.C.

Black

Blower

White

Motor

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 29 - Blower Wiring Diagram for Thermostat-Controlled Models

For..com

108862

Image 18
Contents TM OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationLocal Codes Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap Horizontal Termination Configurations Horizontal HV36 Series 35 min 17 max V42 Series 39 min Corner Installation Horizontal System Installation Using TWO 90 Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingInstalling Optional Blower Accessory Fireplace InstallationParts Lists for Venting Kits and Components Check GAS TypeAttaching Speed Control to Firebox Model BKT Installation Blower Wiring DiagramInstalling GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsREMOVING/REPLACING Glass Door Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door Removing Louver PanelsInstalling LOGS, Lava Rock and Glowing Embers Installing Left Side and Top Brick PanelsInstalling Log No Wiring Diagram Wall Switch InstallationOptional Remote Control Lighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To ApplianceInspecting Burners Operating Optional Blower AccessoryPilot Assembly Burner Flame PatternPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at TopTechnical Service Replacement Parts Service HintsSpecifications Parts Under WarrantyAccessories Illustrated Parts Breakdown Parts List VV36EPS VV36EPH Description QTYBurner Assembly for Models KEY Part Number Description QTY VV42EN, VV42ENS, VV42ENH VV42EP, VV42EPS, VV42EPH VV42ENS VV42ENH Illustrated Parts Breakdown KEY Part Number Description QTY Warranty Information

(V)V36EN specifications

Desa (V)V36EN is a cutting-edge technological solution that combines advanced features and innovative capabilities to enhance user experience and operational efficiency. This state-of-the-art product is designed to cater to a wide range of applications, making it an essential tool across various industries.

One of the standout features of the Desa (V)V36EN is its robust and flexible architecture. This design allows for seamless integration with existing systems, minimizing downtime during implementation and maximizing productivity from the get-go. The system is engineered to support various communication protocols, ensuring compatibility with numerous devices and platforms. This versatility makes it a valuable asset for businesses looking to streamline processes and improve connectivity.

In terms of performance, the Desa (V)V36EN boasts impressive processing capabilities. It utilizes high-speed processors that enable rapid data analysis and decision-making, thereby optimizing workflows. Additionally, featuring advanced data management technologies, the system can handle large volumes of data efficiently. This ensures that users can access critical information in real-time, empowering them to make informed decisions quickly.

Security is another paramount feature of the Desa (V)V36EN. With built-in security protocols and encryption technologies, the system safeguards sensitive information against unauthorized access and cyber threats. This focus on security not only protects business data but also enhances user trust, making it a reliable choice for organizations across various sectors.

User-friendliness is a key characteristic of the Desa (V)V36EN. The intuitive interface ensures that users can navigate the system with ease, requiring minimal training to operate effectively. This aspect significantly reduces the learning curve, allowing teams to adopt the technology rapidly and start reaping the benefits.

Finally, the Desa (V)V36EN is designed with scalability in mind. As businesses grow and evolve, the system can be easily updated and expanded to accommodate increasing demands. Whether it’s integrating new features or scaling up operational capabilities, this flexibility makes it a long-term solution for organizations seeking innovation.

In conclusion, the Desa (V)V36EN stands out as a comprehensive technological solution that combines flexibility, performance, security, user-friendliness, and scalability. It is an ideal choice for organizations looking to improve efficiency, enhance productivity, and stay ahead in a competitive landscape.