Desa (V)V36EN installation manual Table of Contents, Safety Information

Page 2

2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

LOCAL CODES

3

PRODUCT IDENTIFICATION

3

PRODUCT FEATURES

4

PRE-INSTALLATION PREPARATION

4

LOCATION OF TERMINATION CAP

6

VENTING INSTALLATION INSTRUCTIONS

7

FIREPLACE INSTALLATION

16

WIRING DIAGRAM

24

OPERATING FIREPLACE

25

INSPECTING BURNERS

26

CLEANING AND MAINTENANCE

27

TROUBLESHOOTING

28

REPLACEMENT PARTS

30

SPECIFICATIONS

30

SERVICE HINTS

30

TECHNICAL SERVICE

30

ACCESSORIES

31

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

32

WARRANTY INFORMATION

Back Cover

SAFETY INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosions, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

This fireplace must be installed by a qualified (certified or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system. It brings in fresh air for combustion through the outer pipe and combustion gases are exhausted through the inner pipe. If the glass door assembly and venting pipe are not properly seated, connected, and sealed, carbon monoxide leakage (spillage) can occur.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use pro- pane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions

if you cannot reach you gas supplier, call the fire department.

4.Never install the fireplace

in a recreational vehicle

in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front

in high traffic areas

5.This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Al- low surfaces to cool before touching.

6.Carefully supervise young children when they are in the room with fireplace.

For..com

108862

Image 2
Contents For Your Safety What to do if YOU Smell GAS TM OWNER’S Operation Installation ManualFor Your Safety Table of Contents Safety InformationLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap V36 Series 35 min 17 max V42 Series 39 min Horizontal Termination ConfigurationsHorizontal H Corner Installation Horizontal System Installation Using TWO 90 Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingInstalling Optional Blower Accessory Fireplace InstallationParts Lists for Venting Kits and Components Check GAS TypeAttaching Speed Control to Firebox Model BKT Installation Blower Wiring DiagramInstalling GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsREMOVING/REPLACING Glass Door Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door Removing Louver PanelsInstalling LOGS, Lava Rock and Glowing Embers Installing Left Side and Top Brick PanelsInstalling Log No Optional Remote Control Wiring DiagramWall Switch Installation Lighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To ApplianceInspecting Burners Operating Optional Blower AccessoryPilot Assembly Burner Flame PatternPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at TopTechnical Service Replacement Parts Service HintsSpecifications Parts Under WarrantyAccessories Illustrated Parts Breakdown Parts List VV36EPS VV36EPH Description QTYBurner Assembly for Models KEY Part Number Description QTY VV42EN, VV42ENS, VV42ENH VV42EP, VV42EPS, VV42EPH VV42ENS VV42ENH Illustrated Parts Breakdown KEY Part Number Description QTY Warranty Information

(V)V36EN specifications

Desa (V)V36EN is a cutting-edge technological solution that combines advanced features and innovative capabilities to enhance user experience and operational efficiency. This state-of-the-art product is designed to cater to a wide range of applications, making it an essential tool across various industries.

One of the standout features of the Desa (V)V36EN is its robust and flexible architecture. This design allows for seamless integration with existing systems, minimizing downtime during implementation and maximizing productivity from the get-go. The system is engineered to support various communication protocols, ensuring compatibility with numerous devices and platforms. This versatility makes it a valuable asset for businesses looking to streamline processes and improve connectivity.

In terms of performance, the Desa (V)V36EN boasts impressive processing capabilities. It utilizes high-speed processors that enable rapid data analysis and decision-making, thereby optimizing workflows. Additionally, featuring advanced data management technologies, the system can handle large volumes of data efficiently. This ensures that users can access critical information in real-time, empowering them to make informed decisions quickly.

Security is another paramount feature of the Desa (V)V36EN. With built-in security protocols and encryption technologies, the system safeguards sensitive information against unauthorized access and cyber threats. This focus on security not only protects business data but also enhances user trust, making it a reliable choice for organizations across various sectors.

User-friendliness is a key characteristic of the Desa (V)V36EN. The intuitive interface ensures that users can navigate the system with ease, requiring minimal training to operate effectively. This aspect significantly reduces the learning curve, allowing teams to adopt the technology rapidly and start reaping the benefits.

Finally, the Desa (V)V36EN is designed with scalability in mind. As businesses grow and evolve, the system can be easily updated and expanded to accommodate increasing demands. Whether it’s integrating new features or scaling up operational capabilities, this flexibility makes it a long-term solution for organizations seeking innovation.

In conclusion, the Desa (V)V36EN stands out as a comprehensive technological solution that combines flexibility, performance, security, user-friendliness, and scalability. It is an ideal choice for organizations looking to improve efficiency, enhance productivity, and stay ahead in a competitive landscape.