Desa (V)K36EP, (V)K36EN installation manual Wiring Diagram, Optional Remote Control

Page 23

FIREPLACE INSTALLATION

Optional Remote Control Installation

WIRING DIAGRAM

23

FIREPLACE INSTALLATION

Continued

OPTIONAL REMOTE CONTROL

INSTALLATION (Model WRC)

Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation.

1.Open lower louver panel.

2.The WRC model receiver does not require a battery. The re- ceiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 45).

3.Activate the remote handset battery by removing the insulat- ing tab on the back of the handset (see Figure 46). The battery is included pre-installed.

4.Once the battery is activated the unit is ready to use.

5.Close lower louver panel.

Fireplace

Receptacle

Remote Control

Receiver

Extension Cord

Ignition

Module Plug

Figure 45 - Installing the WRC Remote Receiver

Battery Cover

12 Volt Battery

Back of

Handset Pull to Remove

Insulation Tab

Figure 46 - Installing Battery into Back of Handset

WIRING DIAGRAM

INCOMING MAIN

GAS SUPPLY

EV1

EV2

GAS LINE TO

BURNER

Pilot

Burner

Pilot Gas

Line

MV

TH

PV/MV

TR

GND

PV

IGN

24V AC

STEP DOWN

TRANSFORMER

120V AC

WALL SWITCH

(NOT SUPPLIED)

ON

OFF

BLACK

INCOMING

 

WHITE

120V AC

GREEN

(FUSE BOX

OR BREAKER)

 

BLACK

WHITE

GREEN

ELECTRICAL RATING:

120v, 60Hz, 0.7A

OPTIONAL

REMOTE

CONTROL

For morevisit www..com

111924-01B

Image 23
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Exterior Vertical V Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Model BK InstallationAttaching Speed Control to Firebox Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemRemoving Louver Panels Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Removing Glass Door Cleaning Glass DoorWall Switch Installation Installing LOGS, Lava Rock and Glowing EmbersOptional Remote Control Wiring DiagramTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingTop Gas leak. See Warning statement atSpecifications Replacement PartsService Hints Technical ServiceModels Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListBurner Assembly for Models VK36EN, VK36ENH, VK36EP, VK36EPH Parts List Accessories Owners Registration Form Postage Required 111924-01B Warranty Information