16 | VENTING INSTALLATION INSTRUCTIONS |
Parts Lists for Venting Kits and Components | |
| FIREPLACE INSTALLATION |
| Check Gas Type |
| Installing Optional Blower Accessory |
|
|
VENTING INSTALLATION INSTRUCTIONS
Continued
PARTS LISTS FOR VENTING KITS AND COMPONENTS
DESA (5/8") Pipe & Vent Kits
Number | Description |
6" Section Double Wall Pipe, Galvanized | |
12" Section Double Wall Pipe, Galvanized | |
24" Section Double Wall Pipe, Galvanized | |
36" Section Double Wall Pipe, Galvanized | |
48" Section Double Wall Pipe, Galvanized | |
Adjustable | |
| nized |
6" Duravent Collar to FMI Pipe Adaptor (6" Collar/Pipe | |
| Section) |
6" FMI Collar to Pipe Duravent Adaptor (6" Collar/Pipe | |
| Section) |
45° Elbow, Galvanized | |
90° Elbow, Galvanized | |
45° Starter Elbow, Galvanized (Duravent Collar to | |
| FMI Pipe) |
45°Starter Elbow, Galvanized (FMI Collar to Duravent | |
| Pipe) |
Ground Floor Vent Kit | |
Basement Vent Kit | |
Snorkel Vent Kit | |
Roof Vent Kit | |
Corner Vent Kit | |
HTK | Horizontal Round Termination Kit |
Horizontal Round Termination, Galvanized | |
Horizontal Square Termination, Galvanized | |
Vertical Round Termination, Galvanized | |
14" Snorkel Termination, Galvanized | |
36" Snorkel Termination, Galvanized | |
Storm Collar, Galvanized | |
Wall Firestop, Galvanized | |
Roof Flashing - 0 to 6/12 Pitch, Galvanized | |
Roof Flashing - 6/12 to 12/12 Pitch, Galvanized | |
Vertical Restrictor, Galvanized | |
Vinyl Siding Standoff, Galvanized | |
Wall Strap | |
Cathedral Ceiling Support | |
Firestop Plate |
FIREPLACE INSTALLATION
CHECK GAS TYPE
Use proper gas type for the fireplace unit you are installing. If your gas supply is not correct, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type.
INSTALLING OPTIONAL BLOWER
ACCESSORY
NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and dis- connect heater from gas supply. Contact a qualified service person to do this.
WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.
Model BK Installation
Follow all instructions provided in the blower accessory kit.
1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25).
2.Attach green ground wire from power cord to blower housing using screw provided (see Figure 25). Tighten screws securely.
3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25).
Blower
Location
Lower Firebox
Cavity
Side View | Magnetic Strips |
|
Spade Terminals | Exhaust |
| Port |
Stucco Flashing - For use with |
Green
Ground Wire
Figure 25 - Blower Model BK
Screw
For..com