Desa CDV41N/P, CDV37N/P Wireless HAND-HELD Remote Control, REMOVING/REPLACING Glass Door

Page 21

OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

WIRELESS HAND-HELD REMOTE CONTROL

Installing Battery into Receiver

1.

Open bottom louver and locate the

 

switch bracket on the left.

2.

Unscrew the switch bracket. Lean

 

bracket forward so you are able to ac-

 

cess the back of the remote receiver.

3.

Locate the battery clip mounted on the

REMOVING/REPLACING GLASS DOOR

You must remove glass door to install op- tional brick liners, logs, lava rock, and em- ber material.

CAUTION: Do not operate this fireplace with a broken glass door panel. Do not operate this fire- place without the glass door panel securely in place. For replace- ment part information see Re- placement Parts, page 30.

1.Remove the upper louver panel by lift- ing upward and out (see Figure 42).

2.Remove the screws from the three tabs at the top of the glass door while hold- ing door securely keeping it from fall- ing forward.

3.Grasp door by both sides and ease it upward off of the lower bracket (see Figure 43).

4.To replace glass door, follow the above instructions in reverse.

 

back of the receiver. Slide a 9-volt bat-

 

tery (not included) through the clip.

4.

Attach the terminal wires to the battery.

5.

Replace the switch bracket.

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 40- Attaching Battery to Receiver

Installing 9-Volt Battery in Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to a 9-volt bat- tery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

 

Battery

 

Terminal

Cover

Remote

 

Wires

 

Control Unit

9-Volt

 

 

Battery

 

 

 

 

Battery

 

 

Housing

Figure 41 - Installing Battery in Hand- Held Remote Control Unit

Top Louver

Panel

Figure 42 - Removing Top Louver Panel

Screw

Glass Door

Assembly

Lower Bracket for

Glass Door Assembly

Figure 43 - Removing/Replacing Glass Door

Continued

105541

21

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASCDV37N/PA,B and CDV41N/PA,B DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Parts Lists for Venting Kits and Components High Altitude InstallationComfort Glow Rigid Venting Comfort Glow Flexible VentingInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3750/CDA3620T Blowers Check GAS TypePlug in blower power cord Installation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Close manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsInstalling Battery into Receiver Wireless HAND-HELD Remote ControlInstalling 9-Volt Battery in Hand- Held Remote Control Unit REMOVING/REPLACING Glass DoorAttaching Magnetic Decorative Brass Strips Installing Optional Brick Liner CD8037A/ CD8041Replace glass door. See Removing/Re- placing Glass Door, Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsPilot Assembly Operating Optional Blower AccessoryInspecting Burners HAND-HELD Remote OperationGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsService Hints Technical ServiceAccessories SpecificationsTHERMOSTATICALLY- Controlled Blower KIT CDA3620T Manual Blower KIT GA3750CDV41NA,B Illustrated Parts BreakdownDIRECT-VENT Fireplace CDV37NA,B CDV41NA,B Parts ListCDV37PA,B CDV41PA,B DIRECT-VENT Fireplace CDV37PA,B CDV41PA,B Warranty Information