Desa CDV41N/P Specifications, Accessories, THERMOSTATICALLY- Controlled Blower KIT CDA3620T

Page 31

OWNER’S MANUAL

SPECIFICATIONS

 

CDV37N(A,B)

CDV37P(A,B)

CDV41N(A,B)

CDV41P(A,B)

Btu

16,000/22,000 Btu/h

16,000/20,000 Btu/h

17,000/24,000 Btu/h

17,000/22,000 Btu/h

 

 

 

 

 

Gas Type

Natural

Propane/LP

Natural

Propane/LP

 

 

 

 

 

Ignition

Piezo

Piezo

Piezo

Piezo

 

 

 

 

 

Manifold Pressure

3.5" w.c.

10.0" w.c.

3.5" w.c.

10.0" w.c.

 

 

 

 

 

Minimum Inlet Supply Pressure

4.5" w.c.

11.0" w.c.

4.5" w.c.

11.0" w.c.

 

 

 

 

 

Dimension, Inches/mm (HxWxD)

 

 

 

 

Fireplace

33" x 37" x 18 1/2"

33" x 37" x 18 1/2"

35" x 41" x 18 1/2"

35" x 41" x 18 1/2"

 

838 x 940 x 470mm

838 x 940 x 470mm

838 x 1041 x 470mm

838 x 1041 x 470mm

Carton

36" x 39" x 19 1/2"

36" x 39" x 19 1/2"

36" x 43" x 19 1/2"

36" x 43" x 19 1/2"

 

914 x 991 x 495mm

914 x 991 x 495mm

914 x 1092 x 495mm

914 x 1092 x 495mm

 

 

 

 

 

Weight, lbs/kg

 

 

 

 

Fireplace

127 lbs/58 kg

127 lbs/58 kg

137 lbs/62 kg

137 lbs/62 kg

Shipping

130 lbs/59 kg

130 lbs/59 kg

140 lbs/64 kg

140 lbs/64 kg

 

 

 

 

 

ACCESSORIES

Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382. for information. You can also write to the ad- dress listed on the back page of this manual.

BRASS PERIMETER TRIM KIT CD9037(37")/GA7091(41") (Not Shown)

Optional three sided brass trim kit. Provides a finished appearance with the class of brass.

THERMOSTATICALLY- CONTROLLED BLOWER KIT CDA3620T

Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- tions included in this manual.

FREE-STANDING CABINET MANTEL WITH SQUARE LEG STYLING - FINISHED

GMC41F(41") - Walnut Stained Hardwood Veneer

Complete assembly instructions are included along with a three-sided perimeter brass trim kit to cover unfinished fireplace edges.

BRICK LINER CD8037A(37")/ CD8041(41")

(Not Shown)

This brick liner adds a touch of style to your direct-vent fireplace and comes with easy to follow instructions for installation.

MANUAL BLOWER KIT GA3750

Manual variable control blower accessory provides better heat distribution. Complete installation and operation instructions in- cluded in this manual.

FREESTANDING CABINET MANTEL WITH SQUARE LEG STYLING - UNFINISHED

GMC511U(37") Oak Veneer GMC42U(41") Hardwood Veneer

This mantel is unfinished and ready to stain or paint. Complete assembly instruc- tions are included along with a three-sided perimeter brass trim kit to cover unfinished fireplace edges.

105541

31

Image 31
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyCDV37N/PA,B and CDV41N/PA,B DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationGlossary Terms Product FeaturesProduct Identification Local CodesFraming and Finishing PRE-INSTALLATION PreparationClearances Location and Space RequirementsLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Comfort Glow Flexible Venting High Altitude InstallationParts Lists for Venting Kits and Components Comfort Glow Rigid VentingCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3750/CDA3620T BlowersPlug in blower power cord Installation Items Needed Installing GAS Piping to Fireplace LocationPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Close manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Wireless HAND-HELD Remote ControlInstalling Battery into Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitAttaching Magnetic Decorative Brass Strips Installing Optional Brick Liner CD8037A/ CD8041Replace glass door. See Removing/Re- placing Glass Door, Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceHAND-HELD Remote Operation Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Troubleshooting Observed Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsManual Blower KIT GA3750 SpecificationsAccessories THERMOSTATICALLY- Controlled Blower KIT CDA3620TCDV41NA,B Illustrated Parts BreakdownDIRECT-VENT Fireplace CDV37NA,B CDV41NA,B Parts ListCDV37PA,B CDV41PA,B DIRECT-VENT Fireplace CDV37PA,B CDV41PA,B Warranty Information