Desa CDV37N/P, CDV41N/P installation manual Installing Optional Brick Liner CD8037A/ CD8041

Page 22

CDV37N/P(A,B) AND CDV41N/P(A,B)

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

Continued

Attaching Magnetic Decorative Brass Strips

This fireplace comes with a set of two magnetic decorative brass strips. Before attaching strips to fireplace, remove plastic film from brass pieces. After installing the door, attach these strips to the top and bot- tom of the glass door frame.

8.Loosely secure retainer brackets to grate. Brackets are adjustable left to right to allow proper placement of panel. These will hold rear panel in place.

9.Tighten all bracket screws.

10.Follow instructions on page 23 to install logs, lava rock, and ember material.

11.Replace glass door (see page 21).

WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

INSTALLING OPTIONAL BRICK LINER CD8037A/ CD8041

WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before installing brick liner.

This brick liner kit is optional. You may purchase brick liner from your local retailer or see Accessories, page 31.

CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Excessive force will break brick panels.

1.Remove glass door. See Removing/Re- placing Glass Door, pages 21.

2.If installing brick liner in new fireplace, go to step 3. If installing brick liner in an existing fireplace, carefully remove logs, lava rock, and ember material.

3.Install left side brick panel first by slid- ing it between the grate and the side of the firebox (see Figure 44).

4.Slide the left retainer bracket against the left side brick panel. Loosely se- cure the bracket screw. This secures the left side brick panel.

5.Install the right brick panel using the same method described in step 3.

6.Slide the right retainer bracket against the right side brick panel. Loosely se- cure the bracket screw. This secures the right side brick panel.

7.Install rear brick panel. Rest bottom edge of panel on back edge of grate (see Figure 45).

Left Side

Brick Panel

Retainer

Brackets

Figure 44 - Installing Left Side Brick Panel

Rear Brick Panel

Retaining Brackets

Figure 45- Installing Rear Brick Panel and Retainer Brackets

22

105541

Image 22
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyCDV37N/PA,B and CDV41N/PA,B Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPLocal Codes Product FeaturesProduct Identification Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting Comfort Glow Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Comfort Glow Flexible VentingInstalling GA3750/CDA3620T Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypePlug in blower power cord Installing GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureInstalling 9-Volt Battery in Hand- Held Remote Control Unit Wireless HAND-HELD Remote ControlInstalling Battery into Receiver REMOVING/REPLACING Glass DoorInstalling Optional Brick Liner CD8037A/ CD8041 Attaching Magnetic Decorative Brass StripsInstalling LOGS, Lava Rock and Glowing Embers Replace glass door. See Removing/Re- placing Glass Door,Operating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsInspecting Burners Operating Optional Blower AccessoryPilot Assembly HAND-HELD Remote OperationPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsWiring Diagram Technical ServiceTHERMOSTATICALLY- Controlled Blower KIT CDA3620T SpecificationsAccessories Manual Blower KIT GA3750Illustrated Parts Breakdown CDV41NA,BParts List DIRECT-VENT Fireplace CDV37NA,B CDV41NA,BCDV37PA,B CDV41PA,B DIRECT-VENT Fireplace CDV37PA,B CDV41PA,B Warranty Information